Maintenance
3A5083C
11
Maintenance
Pump Maintenance
Refer to your manual (see
for pump maintenance.
Solar Panel and Charge
Controller Maintenance
Refer to the manuals supplied with the solar panel and
charge controller.
Replacing the Fuses
on page 8 for fuse loca-
tion.
Replacement fuses are available from Graco.
•
Voltage Rating: 32 VDC
•
Current Rating: See
on this page
•
Style: Automotive Mini (ATM); UL 248 approved
Fuse Ratings
The battery and controller fuses are determined by the
pump controller. The motor fuse size is determined by
the motor type.
)
NOTICE
Fuses are supplied, and are required on all models.
To avoid equipment damage:
•
Never operate the pump or system without a
fuse installed.
•
A fuse of the correct voltage and amperage
must be installed in line with the power entry
to the system.
•
See
on this page for current
ratings.
F1
Pump Controller
(See pg 3 for identification)
Harrier EZ and EZ-JR
20 A
F2
Motor
120% of current rating on motor.
F3
Solar Charge Controller
(See pg 3 for identification)
ASC 12/12
20 A
ASC 12/8
10 A