Installation
3A6931A
25
3.
Route the CAN cable (502) along the back frame of
the ram. Use the six wire ties (503) to secure the
cable. See
Figure 50
. Coil any excess cable under
the ADM mounting bracket.
4.
Connect the other end of the CAN cable (502) to the
bulkhead connection labeled C1 on the ram junction
box as shown in
Figure 50
.
5.
Install the software as described in the E-Flo SP
Software Instructions. See
Related Manuals
on
page
.
Standalone Pump Transformer
Kit
The pump transformer kit
25E268
is for pumps requiring
480 VAC power. Mount this transformer near the pump
in a secure location that prevents damage to the trans-
former or the wiring to the pump.
Mount the Pump Transformer
1.
Follow the
Pressure Relief Procedure
for the air
motor pump and ram system you are using. See
Related Manuals
on page
2.
Refer to the
Transformer Mounting Hole Diagram
. Use the mounting holes as a guide to
drill holes for 1/4 in. (6 mm) screws.
3.
Attach the transformer securely to the mounting sur-
face.
Connect the Pump Transformer Power
1.
Follow the steps in
Connect Power to the Electric
Pump System
on page
before connecting power
to the transformer.
2.
Remove the four screws on the transformer as
shown in
Figure 51
and remove the front cover.
F
IG
. 50: Junction Box Connection for CAN Cable
503
C1
502
501
All electrical wiring must be done by a qualified elec-
trician and comply with all local codes and regula-
tions.
F
IG
. 51: Pump Standalone Transformer
Remove
Содержание 25E202
Страница 29: ...Installation 3A6931A 29 Notes...