Installation
3A6931A
23
22. Refer to
Connect Power to an Electric Ram
System
to connect power to the ram junction box.
Connect Power to an Electric
Ram System
Refer to the following steps to connect power to the
junction box on the ram system.
1.
Cut power cord wires to the following lengths:
•
Ground wire - 6.5 inches (16.5 cm)
•
Power wires - 3.0 inches (7.6 cm)
•
Add ferrules as necessary. See
Figure 42
.
2.
Remove the six screws holding the cover of the ram
junction box then remove the junction box cover.
3.
Insert the power cord through the cord grip and into
the ram junction box.
4.
Attach the ground wire to the ground terminal inside
the ram junction box.
5.
Tighten the cord grip to securely hold the power
cord to the ram junction box.
6.
Refer to
Figure 45
and connect the wires from the
power cord into terminals 2T1 and 6T3 on the dis-
connect switch terminal block.
7.
Replace the ram junction box cover and secure it
with the six screws that were removed in step 2.
All electrical wiring must be done by a qualified elec-
trician and comply with all local codes and regula-
tions.
NOTICE
To avoid equipment damage, route and secure a
power cord that is long enough to allow the full range
of movement for the ram.
F
IG
. 42: Power Cord
LQ
LQ
F
IG
. 43: Remove the Ram Junction Box Cover
F
IG
. 44: Power Connection
F
IG
. 45: Disconnect Switch Terminal Block
Screws
Ground Terminal
Cord Grip
Disconnect Switch
Terminal Block
1L1 3L2 5L2
2T1 4T2 6T3
Содержание 25E202
Страница 29: ...Installation 3A6931A 29 Notes...