Repair
34
3A5379B
Disconnect Pump from Platen
20, 30, and 60 Liter Platen
1. Perform the
Pressure Relief Procedure
on page
14.
2. Disconnect power from the driver.
3. Loosen two 5/16 in. screws (462) from the platen.
4. Carefully pull the pump away to prevent damage to
the pump inlet. If using a pump with an intake
adapter, remove the screws (472), adapter (471),
and o-rings (473, 463) from the pump inlet.
Connect Platen
20, 30, and 60 Liter Platen
NOTE:
Before installing the 20, 30, or 60 liter platen to a
pump with an intake adapter, install the adapter and
o-ring from mounting kit 257630 using the two set
screws. See F
IG
. 45.
1. Place the o-ring (473) from mounting kit 257630 on
the pump intake. Loosen the mounting bracket
screws (401) and carefully lower the pump onto the
o-ring (463) and platen.
2. Secure the pump’s intake flange to the plate with
screws (401).
Remove Wipers
See
Remove and Reinstall Wipers
on page 18.
Install Wipers
See
Remove and Reinstall Wipers
on page 18.
F
IG
. 45: 20, 30, and 60 liter mounting kit
463
462
Check-Mate Mounting
r_255648_313527_35a