Table
Table
Table 11
11
11 Fields
Fields
Fields on
on
on the
the
the Secondary
Secondary
Secondary Agitator
Agitator
Agitator Setup
Setup
Setup Screen
Screen
Screen
Item
Item
Item
Description
Description
Description
Station Number
The current station number being displayed:
• 1–Maximum number of stations
Station Name
The alphanumeric name of the current station being displayed:
• 0–20 characters
Variable
Frequency Drive
Select the manufacturer of the Variable Frequency Drive/Inverter used to control the
agitator in the Secondary Tank:
• None
None
None (Default)
• Lenze
Lenze
Lenze (Lenze SMVector)
• AB
AB
AB PowerFlex
PowerFlex
PowerFlex 4M
4M
4M (Allen Bradley PowerFlex 4M)
• AB
AB
AB PowerFlex
PowerFlex
PowerFlex 525
525
525 (Allen Bradley PowerFlex 525)
• Mitsubishi
Mitsubishi
Mitsubishi (FR-F800 and FR-E700 series)
For Lenze part numbers, see
Variable Frequency Drive/Inverter (B) 17N041, 17N042,
.
Agitator Profile
Select Enable
Enable
Enable to allow the secondary tank agitator to be controlled by agitator profiles.
Select Disable
Disable
Disable to disable agitator profiles.
See
Set Up Agitator Profile, page 87
, for more information about setting up agitator
profiles.
Production
Enable
Select Enable
Enable
Enable to enable the following features:
• When the system goes into production, it will monitor agitator status and trigger event if
the agitator is idle for xx amount of time. (See the Idle Timer field below.)
• If Agitator Profile is enabled, the agitator will automatically be pushed into profile 1
when in production, and profile 2 when not in production.
Select Disable
Disable
Disable to disable tracking of agitator status and scheduled control of profiles.
Idle Timer
Enter the number of minutes the agitator has not been running before a Primary Agitator
Stopped (H1A0) event is triggered. Production Enable for this station has to be enabled
for an event to trigger.
• 0–999 minutes
NOTE:
NOTE:
NOTE: When Idle Timer is set to 0, systems will not monitor agitator status while in
production.
82
3A4030C