Field
Field
Field
Description
Description
Description
Station Number
The current station number being displayed:
• 1–Maximum number of stations
Station Name
The alphanumeric name of the current station being displayed:
• 0–20 characters
Local / Remote
Control
Select Local
Local
Local to control the selected pump from the Pump Control Module in the
hazardous location.
Select Remote
Remote
Remote to control the selected pump from the Intelligent Paint Kitchen software
in the non-hazardous location.
System Type
Pump type is automatically detected and displayed: Single Lower or Dual Lower.
Pressure Units
Select the units for the pressure of the pump:
• psi
psi
psi
• Bar
Bar
Bar
• MPa
MPa
MPa
Volume Units
Select the units for the volume data of the pump:
• Liters
Liters
Liters
• Gallons
Gallons
Gallons
• cc
cc
cc
Flow Units
Select the units for the pressure flow data of the pump:
• Liters/min
Liters/min
Liters/min: Liters per minute
• Gallons/min
Gallons/min
Gallons/min: Gallons per minute
• cc/min
cc/min
cc/min: Cubic centimeters per minute
• oz/min
oz/min
oz/min: Ounces per minute
• Cycles/min
Cycles/min
Cycles/min: Cycles per minute
Agitator Speed
Units
Select the units for the agitator speed of the pump or tank:
• %
%
%
• Hz
Hz
Hz
• RPM
RPM
RPM
Stop BPR %
Enter a number (0–100) to specify the percentage of back pressure regulation to hold
fluid line pressure when the pump is stopped.
Remote
Run/Stop
Enable/Disable the Remote Run/Stop function.
Closed Loop
Control
Enable/Disable the Closed Loop Control.
Lower Size
The pump lower size is automatically detected and displayed in cubic centimeters: 220
cc, 290 cc, 750 cc, 1000 cc, 1500 cc, 2000 cc, 3000 cc, or 4000 cc
Auxiliary I/O
Function
Select the function:
• Reed
Reed
Reed Switch
Switch
Switch Count
Count
Count: Used to count the cycle rate of the fill pump.
• Agitator
Agitator
Agitator Halt
Halt
Halt: When the pressure switch attached to the tank cover elevator closes, the
pump control automatically disables the primary agitator.
• High
High
High Level
Level
Level Primary
Primary
Primary: Enables output when the Primary Tank level is greater than
the high level setting in percent.
• Low
Low
Low Level
Level
Level Primary
Primary
Primary: Enables output when the Primary Tank level is less than the low
level setting in percent.
• PLC
PLC
PLC: Output control by a remote source.