background image

Kits and Accessories

3A3995L

15

Kits and Accessories

CSP Divider Block Inlet Fittings

 Always connect fittings to Graco designed stud to 

ensure connections.

CSP Divider Block Outlet Doubling Plug

 Torque to10 to12 ft.-lbs (13.56 to 16.27 N•m)

CSP Divider Block Outlet Combination Kits

NOTE: Only used for combination CSP valve outlet 

numbers 1 and 2 (See F

IG

. 16, page 16).

CSP Divider Block Outlet Fittings

NOTE

:

 

Always use Graco outlet fittings for your applications.

 Always connect fittings to Graco designed stud to 

ensure connections.

 Torque to 12 to14 ft.-lbs (16.27 to18.98 N•m)

Used only for connection to nylon tube

†Used for nylon tube with outer diameter of 0.25 +/- 

0.005 in.

Part No. Description

Qty

17L442

FITTING, push to connect, 1/4 in. hose 

stud x 1/8 in. npt male straight, 2000 

psi (13.79 MPa, 137.9 bar)

1

17L449

FITTING, push to connect, 

6 mm stud x 1/8 bspt male 90°, 2000 

psi (13.79 MPa, 137.9 bar)

1

17L545

FITTING, push to connect, 

6mm stud x 1/8 bspt male straight, 

2000 psi (13.79 MPa, 137.9 bar)

1

17L546

FITTING, compression, 6 mm x 1/8 

bspt male 90°, 3000 psi (20.68 MPa, 

206.8 bar)

1

17L548

FITTING, compression, 6 mm x 1/8 

bspt male straight, 3000 psi (20.68 

MPa, 206.8 bar)

1

17T780

FITTING, compression, 6 mm x 1/8 npt 

male straight, 3000 psi (20.68 MPa, 

206.8 bar)

1

17T781

FITTING, compression, 6 mm x 1/8 npt 

male 90°, 3000 psi (20.68 MPa, 206.8 

bar)

1

Part No. Description

Qty

17L651

PLUG, outlet doubling, 3000 psi (20.68 

MPa, 206.8 bar)

1

Part No. Description

Qty

25T510 KITS, combination, 6mm OD steel 

tube, 3000 psi (20.7 MPa, 206.8 bar)

25T511 KITS, combination, 1/4 in. OD steel 

tube, 3000 psi (20.7 MPA, 206.8 bar)

Part No.

Description

Qty

17Y692

★❖

FITTING, compression with check 

valve, 1/4 in. tube, 1000 psi (6.9 MPa, 

69 bar) 

1

17L440

★❖

FITTING, push to connect, 1/4 in. OD 

tube x M10 with check valve, 625 psi 

(4.31 MPa, 43.1 bar)

1

17L441

◆★

FITTING, push to connect, 1/4 in. hose 

stud x M10 with check valve, 2000 psi 

(13.79 MPa, 137.9 bar)

1

17L458

◆★

FITTING, push to connect, 6 mm hose 

stud x M10 with check valve, 2000 psi 

(13.79 MPa, 137.9 bar)

1

17L543

★❖

FITTING, push to connect, valve outlet, 

6 mm OD tube, 1000 psi (6.9 MPa, 69 

bar)

1

17L550

FITTING, compression, valve outlet, 6 

mm OD tube, with check valve, 3000 

psi (20.68 MPa, 206.8 bar)

1

17Y693

ADAPTER, M10 x 1/8 npt female, with 

check valve, 5076 psi (35 MPa, 350 

bar)

1

17Y689

Fitting, push to connect, 6 mm stud x 

1/8 npt male, straight, 2000 psi (13.79 

MPa, 137.9 bar)

20A080

Fitting, compression with check valve, 

valve outlet, 1/4 in. OD steel tube, 

3000 psi (20.7 MPa, 206.8 bar)

1

Содержание 24Z477

Страница 1: ...mum Operating Pressure See page 3 for model information including maximum working pressure and approvals Related Manuals Important Safety Instructions Read all warnings and instructions in this manual...

Страница 2: ...aration Blockage 13 Recycling and Disposal 14 End of Product Life 14 Kits and Accessories 15 CSP Divider Block Inlet Fittings 15 CSP Divider Block Outlet Doubling Plug 15 CSP Divider Block Outlet Comb...

Страница 3: ...8 in npt 8 24Z488 B 1 8 in npt 10 24Z489 B 1 8 in npt 12 24Z490 B 1 8 in npt 14 24Z491 B 1 8 in npt 16 24Z492 B 1 8 in npt 18 24Z493 B 1 8 in npt 20 24Z494 B 1 8 in npt 22 24Z495 B 1 8 in bspp 6 24Z49...

Страница 4: ...essure or temperature rating of the lowest rated system component See Technical Specifications in all equipment manuals Use fluids and solvents that are compatible with equipment wetted parts See Tech...

Страница 5: ...be diverted to the next outlet away from the inlet port When one or more outlets are plugged the output is a multiple of the standard output For example One outlet provides 0 012 cu in 0 2 cc of lubri...

Страница 6: ...ring A system can be set up to use an electronic controller or to use a pump with a built in controller A micro limit proximity switch sensor can be installed to the cycle indicator on the CSP block a...

Страница 7: ...into the adapter 2 Tighten the set screw to within 5 to 7 in lbs 6 to 8 N m 3 Mount the proximity switch assembly to the CSP valve For Series A CSP Valves torque to within 25 to 30 in lbs 2 8 to 3 4...

Страница 8: ...8 3A3995L Wiring Instructions NOTICE The electrical ratings for the system must not be exceeded Overloading the switch can cause it to fail on the first cycle FIG 8 26C823 Flying Lead 26C822 M12 Conne...

Страница 9: ...ed to the inlet port If the lubricant supply is interrupted when restarted the cycle continues from the point it previously stopped Each plunger must complete a full movement before the next plunger c...

Страница 10: ...the left side of Plunger 1 pushing the plunger to the right 3 Plunger 1 opens delivering lubricant to Outlet 1 FIG 10 Sequence 2 1 Lubricant fills the left side of Plunger 2 pushing the plunger to th...

Страница 11: ...plunger to the right 2 Plunger 3 opens delivering lubricant to Outlet 6 FIG 12 Sequence 4 1 Lubricant fills the right side of Plunger 1 pushing the plunger to the left 2 Plunger 1 opens delivering lub...

Страница 12: ...nger to the left 2 Plunger 2 opens delivering lubricant to Outlet 3 FIG 14 Sequence 6 1 The final sequence completes the cycle Lubricant fills the right side of Plunger 3 2 Plunger 3 opens delivering...

Страница 13: ...m of contamina tion is found in a valve cleaning that valve will only tem porarily solve contamination blockage problems The source of the contamination must be eliminated for sat isfactory service Th...

Страница 14: ...the product s useful life dismantle and recycle it in a responsible manner Perform the Pressure Relief Procedure page 9 Drain and dispose of fluids according to applicable regulations Refer to the ma...

Страница 15: ...3000 psi 20 68 MPa 206 8 bar 1 17T780 FITTING compression 6 mm x 1 8 npt male straight 3000 psi 20 68 MPa 206 8 bar 1 17T781 FITTING compression 6 mm x 1 8 npt male 90 3000 psi 20 68 MPa 206 8 bar 1...

Страница 16: ...Kits and Accessories 16 3A3995L FIG 16...

Страница 17: ...9 MPa 69 bar 1 17R567 FITTING push to connect 6 mm tube x 1 8 bspt male straight 1000 psi 6 9 MPa 69 bar 1 17R568 FITTING push to connect 6 mm tube x 1 8 bspt male 90 1000 psi 6 9 MPa 69 bar 1 17R569...

Страница 18: ...mm OD high pressure hose Part No Description Qty 17L437 STUD 90 1 8 in hose x PTC fitting 1 17L438 STUD straight 1 8 in hose x PTC fit ting 1 17L647 SLEEVE hose 1 8 in ID 1 Part No Description Qty 17...

Страница 19: ...hown in FIG 17 Dis card the nuts and plate after the stud welding is com plete Proximity Switch Kit Only available for CSP valves with an indicator pin Part No Description Qty 26A478 KIT weld stud 1 S...

Страница 20: ...Dimensions 20 3A3995L Dimensions This dimension varies and is determined by the number of outlets See No of Outlets page 21 for this dimension...

Страница 21: ...si 350 bar 35 MPa Inlet Connection Size 1 8 in bspp 1 8 in npt Outlet Connection Size M10 x 1 f Maximum Working Temperature 212 F 100 C No of Outlets L page 21 LENGTH 6 outlets 2 4 in 60 mm 8 outlets...

Страница 22: ...n material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRA...

Отзывы: