10
3A3995L
Sequences
Sequence 1
1. Lubricant enters through the inlet provided at the
top of the block.
2. Lubricant fills the left side of Plunger 1 pushing the
plunger to the right.
3. Plunger 1 opens, delivering lubricant to Outlet 1
Sequence 2
1. Lubricant fills the left side of Plunger 2 pushing the
plunger to the right.
2. Plunger 2 opens, delivering lubricant to Outlet 4
F
IG
. 10
Inlet
Outlet
1
Plunger 1
F
IG
. 11
Inlet
Outlet
4
Plunger 2