3.
On each tie bolt (24), place two belleville washers
(27), with the rounded side of first washer toward
the permanently-attached nut and the rounded
side of the second washer away from the nut,
then a flat #12 washer (26).
4.
Slide the tie bolts (24) through the retainers
(9), fluid covers (6), and body (1), all oriented
as shown. Use a clamp to hold the sections
together.
5.
On the threaded end of each tie-bolt (24), place
a flat #12 washer (26), two belleville washer (27),
with the rounded side of the first belleville washer
toward the flat washer and the rounded side of
the second belleville washer away from the flat
washer, and a nut (28). Do not tighten yet.
6.
Using a a small hammer and PVC tool (44), tap a
wearable seat (19) into place on the outlet side
of each fluid cover (6).
7.
Insert a d-ring (21), check ball (22), ball retainer
(20), and o-ring seal (17) on top of each wearable
seat (19).
8.
Align the outlet manifold (8) on the assembly with
the outlet port facing in the correct direction for
your application.
9.
Align the outlet manifold retainers (11) on the
outlet manifold (8).