Installation
6
3A2960G
Installing the Lubrication
Controller
A
1.
Select a flat surface to install the Lubrication
Controller. Drill mounting holes. See
2.
Align the junction box with the pre-drilled holes (F
3).
System Configuration and
Wiring
The
Diagrams (Fig 4 - 6),
Diagrams (Fig 8 - 9), and
(Fig 7) show typical Injector, Series
Progressive and Dual Line lubrication system
configurations.
Refer to Table 1, 2, and 3 to determine the Required
System Configuration, Sensor Configuration, and Wiring
Diagram to use to set up the system.
Table 1: System Configurations
Table 2: Sensor Wiring Configurations
Table 3: Modes of Operation
Automatic System Activation Hazard
Unexpected activation of the lubrication system could
result in serious injury, including skin injection and
amputation. This device has an automatic timer that
activates the lubrication system pump when power is
connected or when exiting the programming function.
Before you install or remove the Lubrication Controller
from the system, disconnect and isolate all power to
the pump, and relieve all pressure.
F
IG
. 3
System
Figure
Page
Injector
4
6
Series Progressive
5
7
Dual Line
6
8
System
Figure
Page
Dry Contact
7
10
Source Switch
8
10
Mode
Power
Figure
Page
Time ON/Time OFF
DC
9
Cycle ON or Pressure
ON/Time OFF
DC
9
Low Level Switch
9