Setup
8
3A2257F
Connecting Lube Lines to Pump: Suction,
Gravity and Pressure Fed Pump Models
Only
NOTE:
The lube line refers to the outlet line supplying
lubricant to the lubrication points.
1.
Apply thread sealant (user supplied) to lube line fit-
ting.
2.
Connect lube line to pump outlet (6), (F
. 8)(also
3.
Torque lube line fitting to 50 + 5 in. lbs (5.65 + 0.6
N.m).
4.
If installed, close the drain valve, located down-
stream from the pump.
5.
Hand prime the pump until clean, air-free oil is flow-
ing through the lube line.
6.
Connect the lube line to the lube point.
7.
After startup, adjust individual pumps to meet
required flow rates. See Adjusting the Pump, page
8.
Alarm Models Only: Installing Pressure
Switch (see Alarm Pump, page 17)
The pump’s check valve is monitored by a pressure
switch. When fluid pressure reaches the check valve
cracking pressure
1.
Apply thread sealant (user supplied) to pressure
switch.
2.
Install pressure switch into sensor output (3) (F
7).
NOTE:
Set switch to 50 psi (3.44 bar, 0.34 MPa).
3.
Set the pumps’ check valve to a cracking pressure
of 95-105 psi (6.55 bar to 7.24 bar / 0.655 MPa to
0.724 MPa)
4.
After startup, ensure switch is activating correctly.
Adjusting the Pump
Pump volume is controlled by an external adjusting
screw (8) (F
. 9). Turning the adjusting screw changes
the length of the piston stroke which changes the pump
discharge volume.
1.
Loosen the adjusting screw locknut (9) (F
. 9).
2.
Turn the adjusting screw (8) (F
. 9):
•
Counterclockwise - increases discharge volume
(drops per stroke)
•
Clockwise - decreases discharge volume (drops
per stroke)
F
IG
. 8
6
I
F
IG
. 9
9
8