background image

Instructions

GBL 7500 Box Lubricator 
Pump 
GBL Shaft Rotation/Low Level 
Alarm Pump

3A2257F

EN

GBL 7500 Box Lubricator Pump: Fully enclosed, self-lubricating, precision, metering pump 
capable of pumping small flows of either mineral or synthetic oil to machinery injection 
points. For professional use only.

GBL Shaft Rotation/Low Level Alarm Pump: Fully enclosed, self-lubricating, precision, 
alarm pump capable of sensing shaft rotation and oil low level. For professional use only.

3/16” models: 7500 psi (51.7 MPa, 517 bar) Maximum Working Pressure
1/4” models: 6000 psi (41.4 MPa, 414 bar) Maximum Working Pressure
3/8” models: 3500 psi (24.1 MPa, 241 bar) Maximum Working Pressure
Alarm Pump: 500 psi (3.4 MPa, 34.4 bar) Maximum Working Pressure

Models: 

Suction Models

24J391 - 3/16” 

24J392 - 1/4”

24J393 - 3/8”

Gravity Models

24J394 - 3/16” 

24J395 - 1/4”

24J396 - 3/8”

Pressure Models

24J397 - 3/16” 

24J398 - 1/4”

24J399 - 3/8”

Alarm Pump Model

24K466

Important Safety Instructions

Read all warnings and instructions in this 
manual. Save these instructions.

Suction Model Shown

II 2G Ex hT6 Gb

Содержание 24J391

Страница 1: ...otation and oil low level For professional use only 3 16 models 7500 psi 51 7 MPa 517 bar Maximum Working Pressure 1 4 models 6000 psi 41 4 MPa 414 bar Maximum Working Pressure 3 8 models 3500 psi 24...

Страница 2: ...h your hand body glove or rag Follow the Pressure Relief Procedure when you stop dispensing and before cleaning checking or servicing equipment Tighten all fluid connections before operating the equip...

Страница 3: ...immediately with genuine manufac turer s replacement parts only Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure all equipmen...

Страница 4: ...reservoir cover FIG 1 NOTE Alarm Pumps Only For optimum perfor mance mount alarm pump in location furthest from drive motor For Gravity and Pressure Fed pumps skip Step 3 and continue installation wi...

Страница 5: ...d Use filtered oil when priming the pump Filter oil with minimum 25 micron strainer Machine requirements may require a higher cleanliness level Maximum allowable inlet pressure Pressure Fed Pump 100 p...

Страница 6: ...l air has been expelled Gravity Fed Models FIG 5 NOTE In the following instructions the fill line refers to the inlet line 1 Remove and discard the sight well plug 1 and out let plug 5 2 Fill the sigh...

Страница 7: ...ace the sight well plug 1 taking care to not allow any thread sealant into the sight well 2 5 Torque sight well plug 1 to 35 5 in lbs 3 95 0 6 N m NOTE Fluid is pumped from the reservoir through a man...

Страница 8: ...ling Pressure Switch see Alarm Pump page 17 The pump s check valve is monitored by a pressure switch When fluid pressure reaches the check valve cracking pressure 1 Apply thread sealant user supplied...

Страница 9: ...the amount of oil discharged by the pump The pump volume can be adjusted using the adjusting screw 8 FIG 9 to change the piston stroke See Adjusting the Pump Calculating Pints per Day Calculating Mini...

Страница 10: ...than form drops in sight glass Table 2 Fluid Measurement Conversion Data Piston Diameter Max Outlet Pressure Drops Stroke1 2 Cubic Inch Stroke Cubic cm Stroke inches mm psi MPa bar Min Max Min Max Mi...

Страница 11: ...ged or worn Fluid flow from pump outlet when pump is not running Inlet pressure exceeds outlet check pressure Reduce inlet pressure to below out let check pressure Pump outlet check ball and or seat i...

Страница 12: ...he oil level in the sight well 2 fall below the pump body surface 1 Remove the sight well plug 1 2 Allow the pump to continue to operate and manually fill the sight well 2 with filtered oil to below t...

Страница 13: ...MPa 414 bar All 3 8 Piston Models 3500 psi 24 1 MPa 241 bar Alarm Pump 500 3 4 MPa 34 4 bar Inlet Size Gravity Fed Models 1 8 27 NPTF Pressure Fed Models 1 4 18 NPTF Outlet Size Suction Gravity Pressu...

Страница 14: ...50 12 70 D Pump Min 2 58 Pump Max 3 18 Pump Min 65 53 Pump Max 78 23 E 5 37 136 40 F Min 4 14 Max 4 90 Min 105 20 Max 124 50 G 1 50 38 10 H 0 50 12 70 J 0 50 12 70 K 0 39 9 90 L 0 92 23 37 M 0 28 7 1...

Страница 15: ...Technical Data 3A2257F 15 Gravity Fed Pressure Fed Inlet P A Outlet C D Outlet Inlet A B C D...

Страница 16: ...Technical Data 16 3A2257F Suction Fed Outlet C D A P N Inlet...

Страница 17: ...Technical Data 3A2257F 17 Alarm Pump C D P N Inlet R Return to Reservoir 1 4 NPT Sensor Output ti26974...

Страница 18: ...of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY...

Отзывы: