Warnings
313939E
3
Warnings
Pressure Relief Procedure
1.
Close the supply pump’s bleed-type master air valve
(required for pneumatic systems) or close individual
inlet ball valve to isolate reel from distribution sys-
tem (F
. 1).
2.
Open dispensing valve into a waste container until
pressure is relieved (F
. 2).
3.
Leave the dispense valve open until you are ready
to use the system again.
If you suspect that the dispensing valve, extension, or
grease fitting coupler is clogged, or that pressure has
not been fully relieved after you have followed the steps
above,
very slowly
loosen the coupler or hose end cou-
pling to relieve the pressure gradually, then loosen it
completely. Then clear the clog.
WARNING
SKIN INJECTION HAZARD
High-pressure fluid from dispense device, hose leaks, or ruptured components will pierce skin. This may look like
just a cut, but it is a serious injury that can result in amputation.
Get immediate surgical treatment.
•
Do not point dispense device at anyone or at any part of the body.
•
Do not put your hand over the end of the dispense outlet.
•
Do not stop or deflect leaks with your hand, body, glove, or rag.
•
Follow
Pressure Relief Procedure
in this manual, when you stop dispensing and before cleaning, checking, or
servicing equipment.
F
IG
. 1
F
IG
. 2