background image

Warnings 

2

308687L

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When 
these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-spe-
cific hazard symbols and warnings not covered in this section may appear throughout the body of this manual 
where applicable.

+

SKIN INJECTION HAZARD

 

High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This 
may look like just a cut, but it is a serious injury that can result in amputation. 

Get immediate surgi-

cal treatment.

Do not point dispensing device at anyone or at any part of the body.

Do not put your hand over the fluid outlet.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Follow the 

Pressure Relief Procedure

 when you stop dispensing and before cleaning, checking, 

or servicing equipment. 

Tighten all fluid connections before operating the equipment.

Check hoses and couplings daily. Replace worn or damaged parts immediately.

FIRE AND EXPLOSION HAZARD

 

When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be 
aware that flammable fumes can ignite or explode. To help prevent fire and explosion:

Use equipment only in well ventilated area.

Eliminate all ignition sources, such as cigarettes and portable electric lamps.

Ground all equipment in the work area.

Keep work area free of debris, including rags and spilled or open containers of solvent and gaso-
line.

Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.

Use only grounded hoses.

Stop operation immediately 

if static sparking occurs or you feel a shock

.

 Do not use equipment 

until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

PRESSURIZED EQUIPMENT HAZARD

Over-pressurization can result in equipment rupture and serious injury.

Do not exceed the maximum air input pressure.

Fill slowly to avoid over pressurizing reservoir.

Use tubing, hoses and other components with pressure ratings equal to or higher than the pump 
rating.

Содержание 239824

Страница 1: ...h petroleum based and synthetic oil antifreeze and windshield washer fluid only Model 239824 500 psi 3 4 MPa 34 bar Maximum Working Pressure 5 gpm 19 lpm Maximum Flow Rate Important Safety Instructions Read all warnings and instructions in this manual Save these instructions ...

Страница 2: ...ment Tighten all fluid connections before operating the equipment Check hoses and couplings daily Replace worn or damaged parts immediately FIRE AND EXPLOSION HAZARD When flammable fluids are present in the work area such as gasoline and windshield wiper fluid be aware that flammable fumes can ignite or explode To help prevent fire and explosion Use equipment only in well ventilated area Eliminate...

Страница 3: ...turer s replacement parts only Do not alter or modify equipment Alterations or modifications may void agency approvals and cre ate safety hazards Make sure all equipment is rated and approved for the environment in which you are using it Use equipment only for its intended purpose Call your distributor for information Route hoses and cables away from traffic areas sharp edges moving parts and hot ...

Страница 4: ...red Part No 235998 Install downstream from the pump C In line filter D In line electronic meter All electrical wiring must be done by a qualified elec trician and comply with all local codes and regula tions Do not use the IM5 In line Electronic Meter in sys tems where the operating pressure exceeds the max imum pressure of the meter or any other component in the system NOTICE Do not use PTFE tape...

Страница 5: ...rt of the dispense valve firmly to the side of a grounded metal pail then trigger the valve Factory Settings The meter is factory calibrated for 10W 30 oil and the default unit of measurement is quarts For other fluids and different units of measurement see Changing the Measurement Units and Calibration Factor on page 8 The equipment must be grounded to reduce the risk of static sparking Static sp...

Страница 6: ...ed total is shown in gallons when the unit of measurement is set in gallons quarts or pints The accumulated total is shown in liters when the measure ment is set in liters The meter accumulates a running total of up to 99 999 gallons or liters dispensed before returning to zero See Fig 3 Function of RESET Press and hold the RESET key to clear the digital dis play after each dispense cycle NOTE Alw...

Страница 7: ...e calibration factor press the TOTAL button again to use the existing calibration factor and to resume normal operation To change the calibration factor do steps 4 and 5 4 Dispense exactly one liter of fluid into a calibrated 1 liter container For proper calibration you must dispense exactly 1 liter according to the markings on the container NOTE If you dispense more than 1 liter press the TOTAL b...

Страница 8: ... electronic components of the control Do not remove the black cover over the electronic area when you replace the battery There are no user replaceable components under this cover Do not lay anything on the electronics Do not twist or force parts Align parts properly as instructed To avoid malfunction or high pressure fluid spray do not remove the metal cover of the metering unit There are no user...

Страница 9: ...ering unit 4 together Torque the screws to 15 20 in lb 1 7 to 2 3 N m or until no gap exists between the electronic control and the metering unit Electronic Control Replacement Procedure FIG 6 1 Relieve Pressure see procedure in previous sec tion 2 Remove the four screws 3 holding the electronic control 1 and metering unit 4 together 3 Remove the battery See Battery Replacement Procedure in the pr...

Страница 10: ...lastic housing 8 Install the four screws 3 holding the electronic control 1 to the metering unit 4 together Torque the screws to 15 20 in lb 1 7 to 2 3 N m or until no gap exists between the electronic control and the metering unit NOTICE To avoid pinching the battery wires install the bat tery as shown in FIG 5 The battery wire should extend to the far side of the battery compartment NOTICE Closi...

Страница 11: ...Battery is low Replace the battery See Battery Replacement Procedure page 9 and Technical Data page 13 for recommended battery Electronic control is malfunctioning Replace electronic control See Electronic Control Replacement Procedure page 9 There is no fluid flow Metering unit is malfunctioning Replace the meter Strainer if used is clogged Remove and clean or replace strainer using Strainer Kit ...

Страница 12: ...er before the meter or before the valve on the meter valve combination Install the o ring after the strainer to hold the strainer in place See FIG 9 Thermal Relief Kit 235998 1 2 14 npt m x 1 2 14 npt f Install downstream from the pump FIG 7 Ref Part Description Qty 1 245598 CONTROL electronic 1 2 113930 GASKET 1 3 113941 SCREW 4 4 UNIT metering cannot be sold separately 1 Screws 3 and Gasket 2 ar...

Страница 13: ...x accuracy is 1 25 percent Repeatability 0 15 percent Measured at 2 5 gpm 9 5 lpm at 70 F 21 C with 10 weight oil and 1 gallon dispensed Inlet Outlet Meter can be installed with flow in either direction 1 2 npt Temperature Operating temperature range 4 F to 122 F 20 C to 50 C Storage temperature range 13 F to 122 F 25 C to 50 C Materials of Construction Wetted parts nickel zinc LCP nitrile rubber ...

Страница 14: ...rial or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty s...

Отзывы: