background image

20

309668

Service

Diaphragm Repair

Tools Required

D

Torque wrench

D

One 7/16” (11 mm) and two 1/2” (13 mm) 

socket wrenches

D

Phillips screwdriver

D

O-ring pick

D

13/32” EZY-OUT bearing extractor

D

Rubber mallet

D

Vise with soft jaws

Disassembly

NOTE:

A Fluid Section Repair Kit is available. Parts

included in the kit are marked with an asterisk, for

example (401*). Use all the parts in the kit for the best

results.

WARNING

To reduce the risk of serious injury whenever you

are instructed to relieve pressure, always follow the

Pressure Relief Procedure

 on page 9.

1.

Relieve the pressure.

 Disconnect all hoses.

2. Remove the air valve from the pump (see page

13).

3. Remove the manifolds (102) and disassemble the

ball check valves as explained on page 18. Always

replace the o-rings (108) with new ones.

4. Using a 7/16” socket wrench, remove the clamp

nuts (113) and the grounding strip (112). Loosen

the clamps (111) and slip them over the housing

(1). Pull the covers (101) off the pump, then

remove the clamps from the housing. See the

Detail in Fig. 11.

5. Using a 1/2” socket wrench on both outer dia-

phragm plates (103), unscrew one plate from the

diaphragm shaft (23). Remove one diaphragm

(401), inner diaphragm plate (118), and o-ring

(404). Pull the opposite diaphragm assembly and

the diaphragm shaft out of the pump housing (1).

See Fig. 11. Clamp the shaft in a vise with soft

jaws and unscrew the outer plate (103), then

disassemble the remaining diaphragm assembly.

6. Inspect the diaphragm shaft (23

}

) for wear or

scratches. If it is damaged, check the bearings

(31

}

) also. Replace parts as needed. To remove

the bearings, place a 13/32 EZY-OUT in a vise.

Position the pump housing (1) over the EZY-OUT

(see Fig. 11). Turn the housing in the direction

shown by the arrows to remove the bearing.

7. Hook the shaft seals (30

}

) with an o-ring pick and

pull them out of the housing (1).

8. Clean all parts and inspect for wear or damage.

Replace parts as needed.

Содержание 234192

Страница 1: ...in this manual Save these instructions herkules 338 Air Operated Diaphragm Pump 100 psi 0 7 MPa 7 bar Maximum Fluid Working Pressure 100 psi 0 7 MPa 7 bar Maximum Air Input Pressure Model No 234192 A...

Страница 2: ...nt D Use the equipment only for its intended purpose If you are not sure call your herkules distributor D Do not alter or modify this equipment Use only genuine herkules parts and accessories D Check...

Страница 3: ...lt in a fire or explosion and serious injury D Ground the equipment Refer to Grounding on page 5 D Never use a polypropylene pump with non conductive flammable fluids as specified by your local fire p...

Страница 4: ...he Technical Data section of all equipment manu als Read the fluid and solvent manufacturer s warnings WARNING Safe Operating Temperature Minimum 40_F 4 4_C Maximum 150_F 66_C Operating outside these...

Страница 5: ...r resistivity of your fluid The resistivity must be less than 2 x 1012 ohm centimeters WARNING To reduce the risk of static sparking ground the pump and all other equipment used or located in the pump...

Страница 6: ...ctive flexible air hose C between the accessories and the 1 4 npt f pump air inlet Use a minimum 1 4 6 3 mm ID air hose Screw an air line quick disconnect coupler D onto the end of the air hose C and...

Страница 7: ...r example from an underground tank Overpressurization can also occur if the herkules pump is being used to feed fluid to a piston pump and the intake valve of the piston pump does not close causing fl...

Страница 8: ...exhaust port PRESSURIZED EQUIPMENT HAZARD To reduce the risk of serious eye injury from ice particles never operate the pump with the air exhaust port open Ice may form during pump operation and ice...

Страница 9: ...d section may rupture Always follow the Pressure Relief Procedure above before lifting the pump WARNING 1 Be sure the pump is properly grounded Read FIRE OR EXPLOSION HAZARD on page 3 2 Check all fitt...

Страница 10: ...rings 3 6 and or valve cup 5 and plate 13 are broken or damaged Replace these parts See pages 15 16 The pump cycles at stall or fails to hold pressure at stall The check valves or o rings 108 are leak...

Страница 11: ...d in the exhaust air The diaphragm 401 is ruptured Replace the diaphragm See page 20 The outer diaphragm plates 103 are loose Tighten the plates See page 20 The pump exhausts air at stall The air valv...

Страница 12: ...atible solvent Before storing the pump always flush the pump and relieve the pressure Tightening Threaded Connections Before each use check all hoses for wear or damage and replace as necessary Check...

Страница 13: ...fer to the Valve Plate Detail in Fig 5 Remove the two screws 10 holding the valve plate 13 to the pump Use an o ring pick to remove the valve plate seal 12 and bearing 9 4 Apply grease 26 to the beari...

Страница 14: ...1 3 2 21 01458 1 VALVE PLATE DETAIL GREASE APPLICATION 19 15 Torque oppositely and evenly to 8 to 14 in lb 0 9 to 1 6 N m Torque to 5 to 7 in lb 0 6 to 0 8 N m Apply grease 26 3 112 1 2 4 4 9 12 13 1...

Страница 15: ...and shift saddle 14 See Fig 6 4 Disassemble the link assembly consisting of the actuator link 16 spacer 17 detent link 22 spring 3 stop 4 and valve cup 5 5 Remove the detent ball 8 and spring 6 The d...

Страница 16: ...allet 20 1 1 1 1 2 H 5 Grease the detent link 22 and link spacer 17 Assemble the detent link link spacer and actuator link 16 as shown in Fig 8 The raised bumps on the links 22 and 16 must face up 6 S...

Страница 17: ...n Fig 9 Hold the link assembly firmly in place and install the screw 15 Torque to 7 to 9 in lb 0 8 to 1 0 N m Install the o ring 19 on the cover 2 9 Reinstall the air valve as explained on page 13 Fig...

Страница 18: ...pump leaving the four nuts 106 on the rods Remove the feet 107 and lower manifold 102 5 Remove the outer o ring 108 seat 201 ball 301 ball guide 202 and inner o ring 108 from each of the covers 101 6...

Страница 19: ...01 202 201 202 106 106 1 3 4 2 Apply thread lubricant Do not over torque Flat side faces ball Beveled end up Torque to 50 to 60 in lb 5 6 to 6 8 N m See Torque Se quence page 26 5 301 108 108 301 108...

Страница 20: ...he grounding strip 112 Loosen the clamps 111 and slip them over the housing 1 Pull the covers 101 off the pump then remove the clamps from the housing See the Detail in Fig 11 5 Using a 1 2 socket wre...

Страница 21: ...CAUTION Do not over torque the outer diaphragm plates 103 Doing so will damage the hex heads 4 When installing the covers 101 slip the clamps 111 over the housing 1 before positioning the covers See t...

Страница 22: ...se shaft Do not over torque Round side must face toward diaphragm Flat side faces ball Beveled end up Apply medium strength blue LoctiteR or equivalent Torque to 75 to 85 in lb 8 5 to 9 6 N m at 100 r...

Страница 23: ...in 19 mm long see below and page 24 7 Digit Ref No Part No Description Qty 16 187724 LINK actuator sst 1 17 188175 SPACER link acetal 1 18 111750 WASHER plain sst 1 19 111624 O RING buna N 1 20 111625...

Страница 24: ...parts list on page 23 Y Replacement Danger and Warning labels tags and cards are available at no cost Included in Diaphragm Shaft Kit 239014 which may be purchased separately Not supplied with Polypro...

Страница 25: ...01 COVER fluid acetal with conductive sst fibers 2 102 239146 MANIFOLD acetal with conductive sst fibers BSPT 2 103 187711 PLATE fluid side acetal 2 104 188999 ROD tie 5 16 18 4 106 117233 NUT 5 16 18...

Страница 26: ...ructed to torque fasteners 1 Left Right Fluid Covers Torque bolts to 50 60 in lb 5 6 6 8 NSm FRONT VIEW 1 2 2 Outlet Manifold Torque bolts to 50 60 in lb 5 6 6 8 NSm TOP VIEW 3 4 6 5 4 6 3 Inlet Manif...

Страница 27: ...red per ISO standard 9614 2 Loctiter is a registered trademark of the Loctite Corporation Santoprener is a registered trademark of the Monsanto Company 0 20 40 60 80 100 120 0 1 2 3 4 5 6 7 8 TEST CON...

Страница 28: ...171 2 mm 8 in 203 mm WALL VIEW 07316B 0 28 in 7 mm Diameter 4 3 50 in 89 mm 6 30 in 160 mm 7 24 in 184 mm FRONT VIEW 1 13 in 28 5 mm 1 06 in 27 mm 1 4 npt f Air Inlet 3 8 npt f Air Exhaust muffler inc...

Страница 29: ...309668 29 Notes...

Страница 30: ...to you 1 800 444 4351 Toll Free All written and visual data contained in this document reflects the latest product information available at the time of publication herkules reserves the right to make...

Отзывы: