309668
27
Technical Data
Pumps with PTFE Diaphragms
Maximum fluid working pressure
100 psi (0.7 MPa, 7 bar)
. . .
Air pressure operating range
20 to 100 psi
. . . . . . . . . . . . . . . .
(0.14 to 0.7 MPa, 1.4 to 7 bar)
Maximum air consumption
5.5 SCFM (see chart)
. . . . . . . . . .
Maximum free flow delivery
6.5 gpm (24.6 l/min)
. . . . . . . . . . .
Maximum pump speed
330 cpm
. . . . . . . . . . . . . . . . . . . . . . . . .
Maximum suction lift
7 ft (2.1 m) dry; 12 ft (3.7 m) wet
. . . . . .
Maximum size pumpable solids
1/16 in. (1.6 mm)
. . . . . . . . . .
Sound power level,
at full flow: (100 psi [0.7 MPa, 7 bar)
85 dBa
. . . . . . . . . . . .
Sound power level,
at 70 psi (0.48 MPa, 4.8 bar) and 1 gpm (3.8 lpm) 78 dBa
Operating temperature range
40 to 150
_
F
. . . . . . . . . . . . . . . .
(4.4 to 65.5
_
C)
Air inlet size
1/4 npt(f)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid inlet and outlet size.
3/8 npt(f)
. . . . . . . . . . . . . . . . . . . . . .
Wetted parts
.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Acetal models include acetal with conductive sst fibers.
Non-wetted external parts
acetal, polyester (labels),
. . . . . . . .
glass-filled polypropylene with conductive SST fibers,
303, 304 and 316 stainless steel
Weight
Acetal Pump:
5.25 lb (2.4 kg)
. . . . . . . . . . . . . . . . . . . . .
* Sound power level measured per ISO standard 9614–2.
Loctite
r
is a registered trademark of the Loctite Corporation.
Santoprene
r
is a registered trademark of the Monsanto
Company.
0
20
40
60
80
100
120
0
1
2
3
4
5
6
7
8
TEST CONDITIONS
Pump tested in water with inlet submerged.
(7.6)
(15.2)
(22.7)
(30.3)
(2.8)
(1.4)
(4.2)
KEY
FLUID PRESSURE AND FLOW
SCFM AIR CONSUMPTION
100 psi air
(7 bar)
Example of Finding Pump Air Consumption and Air Pressure at a Specific Fluid Deliv-
ery and Discharge Head:
To supply 3 gpm (11.4 liters) fluid flow (horizontal scale) at 50 psi
(3.5 bar) discharge head pressure (vertical scale) requires 3 scfm (.084 m
#
/min) air con-
sumption at 70 psi (4.9 bar) inlet air pressure.
FLUID FLOW GPM (lpm)
70 psi air
(4.9 bar)
40 psi air
(2.8 bar)
5 scfm
(0.14 m
#
/min)
psi
(bar)
feet
(meters)
280
(85.3)
240
(73.2)
200
(61.0)
160
(48.8)
120
(36.6)
80
(24.4)
40
(12.2)
0
0
20
40
60
80
100
0
5
10
15
20
25
PUMPING RATE DECREASE AT DIFFERENT SUCTION LIFTS
SUCTION LIFT IN FEET (METERS)
(1.52)
(3.05)
(4.57)
(6.1)
(7.62)
EXAMPLE:
At a suction lift of 10 ft (3.05 m), the pump flow rate will be decreased by 20 percent.
(5.6)
(7.0)
(8.4)
20 psi air
(1.4 bar)
3 scfm
(.084 m
#
/min)
(3.8)
(11.4)
(19.0)
(26.5)