background image

32

308813

Graco Standard Warranty

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the
date of sale by an authorized Graco distributor to the original purchaser for use.  With the exception of any special, extended, or limited
warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment
determined by Graco to be defective.  This warranty applies only when the equipment is installed, operated and maintained in accor-
dance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by
faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub-
stitution of non–Graco component parts.  Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of
Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture,
installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for
verification of the claimed defect.  If the claimed defect is verified, Graco will repair or replace free of charge any defective parts.  The
equipment will be returned to the original purchaser transportation prepaid.  If inspection of the equipment does not disclose any defect
in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and
transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT
NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. 

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above.  The buyer agrees that no other
remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any
other incidental or consequential loss) shall be available.  Any action for breach of warranty must be brought within two (2) years of the
date of sale.

Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection
with accessories, equipment, materials or components sold but not manufactured by Graco.  These items sold, but not manufactured
by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer.  Graco will provide
purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment
hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract,
breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings
entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English.  Les parties reconnais-
sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires
exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les  procedures concernées.

Graco Information

TO PLACE AN ORDER

, contact your Graco distributor, or call one of the following numbers 

to identify the distributor closest to you: 

1–800–367–4023 Toll Free

612–623–6921

612–378–3505 Fax

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Sales Offices:

 Minneapolis, Detroit

International Offices:

 Belgium, Korea, Hong Kong, Japan

www.graco.com

PRINTED IN USA 308813  10/1998, Revised 7/2003

Содержание 233670

Страница 1: ...c Airless Spray Gun 4000 psi 28 MPa 280 bar Maximum Working Fluid Pressure Part No 239786 Series A Standard Spray Gun Includes GG0 series tip of choice Part No 241469 Series A Acid Catalyzed Fluid Spr...

Страница 2: ...parts immediately Do not exceed the maximum working pressure of the lowest rated system component This equip ment has a 4000 psi 28 MPa 280 bar maximum working pressure Route the hoses away from the t...

Страница 3: ...onnections before operating the equipment Check the hoses tubes and couplings daily Replace worn damaged or loose parts immediately Permanently coupled hoses cannot be repaired replace the entire hose...

Страница 4: ...to the threads and mating faces of the man ifold 101 a plug 109 and an elbow 107 supplied unassembled Install an elbow 107 in one fluid port of the manifold and a plug 109 in the other port Install th...

Страница 5: ...of the object being sprayed All Manifolds To mount the gun on a stationary support see Fig 3 Also refer to the mounting hole layout on page 30 Attach the gun to the support with two M5 x 0 8 capscrews...

Страница 6: ...inlet accepts 1 4 in 6 3 mm O D tubing Fluid Line and Accessory Recommendations WARNING INJECTION HAZARD To reduce the risk of property damage or serious injury including injection which could be caus...

Страница 7: ...ubing F Fluid Inlet 1 4 18 nptf or 5 JIC 1 2 20 unf G Fluid Outlet circulating gun only 1 4 18 nptf or 5 JIC 1 2 20 unf G or F FAN CYL ATOM Manifold 244930 This manifold is equipped with passages for...

Страница 8: ...rs and hydraulic power sup plies Ground them according to the manufacturer recommendations 3 Air fluid and hydraulic hoses connected to the pump Use only electrically conductive hoses with a maximum o...

Страница 9: ...e connected to the fluid pressure gauge in a system with fluid regulation to help relieve fluid pressure in the hose and gun Triggering the gun to relieve pressure may not be sufficient Have a contain...

Страница 10: ...n a consistent distance 8 to 10 inches 200 to 250 mm from the surface of the object being sprayed Clean the Spray Gun and System Daily WARNING INJECTION HAZARD To reduce the risk of an injection injur...

Страница 11: ...spray tip Maintain metal to metal contact between the gun and the flushing pail Use the lowest possible pressure NOTE Flush the pump and gun before the fluid can dry in it If it is available the flus...

Страница 12: ...iently tightened or gasket 11 is missing or worn from multiple uses Clean or replace the seat 10 and gasket 11 The gasket must be replaced whenever you remove the seat from the gun Tighten nut 7 or re...

Страница 13: ...pring is in position Replace o ring 22 Do not immerse piston in solvent Spray Pattern Troubleshooting Problem Cause Solution Fluttering spray Insufficient fluid supply Air in paint supply line Adjust...

Страница 14: ...emoving it from the gun If the needle is bent it must be re placed 7 Pull the needle assembly 12 straight out the front of the gun Remove the o rings 31 from the fluid needle 12 8 Remove the gasket 11...

Страница 15: ...ed or replaced to avoid fluid leakage 1 2 2 2 3 3 3 3 3 5 Cutaway View 8 1 3 3 4 5 Torque to 20 25 ft lb 27 34 N m 6 6 Torque to 4 5 in lb 0 45 0 56 N m 7 Apply semi permanent anaerobic sealant 7 Tigh...

Страница 16: ...1 12 31 15 14 2 3 5 6 4 18 20 19 17 16 12 Ref 22 21 23 T 25 26 14 1 13 1 2 2 2 3 3 3 3 3 3 3 4 5 Used on non circulating guns only 8 1 32 6 7 8 Apply semi permanent anaerobic sealant 8 Tighten cap 18...

Страница 17: ...tall a new gas ket may result in fluid leaking into the air chamber 6 Install the o rings 31 on the fluid needle assem bly 12 Lubricate with light weight oil CAUTION Be sure to keep the needle straigh...

Страница 18: ...1 1 241468 NEEDLE ASSEMBLY 3 16 in plastic ball used with Part No 241469 includes item 31 1 13 114134 GASKET polyethylene 1 14 114135 SCREW cap socket head M5 x 0 8 45 mm long 4 15 114136 SCREW cap so...

Страница 19: ...1 12 31 15 14 2 3 5 6 4 18 20 19 17 16 12 Ref 22 21 23 25 26 14 1 13 32 1 1 1 1 Model 233670 gun uses a different tip 9 tip nut 7 and a gasket 8 and the seat 10 does not include a diffuser Model 23367...

Страница 20: ...stainless steel Part No 241162 only 2 109 101970 PLUG pipe 1 4 18 ptf stainless steel not shown install one in the fluid outlet port in non circulating applications 3 8673A 101 105 103 107 1 Flats mus...

Страница 21: ...GG0511 12 13 300 325 GG0611 0 013 0 330 2 2 5 50 63 0 18 0 69 GG0113 4 4 5 100 113 GG0213 6 6 5 150 163 GG0313 8 8 5 200 213 GG0413 10 10 5 250 263 GG0513 12 13 300 325 GG0613 14 15 350 375 GG0713 Flo...

Страница 22: ...15 GG0223 6 6 5 150 163 GG0323 8 8 5 200 213 GG0423 10 10 5 250 263 GG0523 12 13 300 325 GG0623 14 15 350 375 GG0723 16 17 400 425 GG0823 18 19 450 475 GG0923 Orifice Fan Width Flow Rate Part No Orifi...

Страница 23: ...213 GG0435 10 10 5 250 263 GG0535 12 13 300 325 GG0635 14 15 350 375 GG0735 16 17 400 425 GG0835 18 19 450 475 GG0935 22 23 550 575 GG1135 24 25 600 625 GG1235 Orifice Fan Width Flow Rate Part No Ori...

Страница 24: ...0 625 GG1251 28 29 700 725 GG1451 0 053 1 35 10 10 5 250 263 3 02 11 4 GG0553 0 055 1 40 8 8 5 200 213 3 25 12 3 GG0455 10 10 5 250 263 GG0555 12 13 300 325 GG0655 28 29 700 725 GG1455 Orifice Fan Wid...

Страница 25: ...GG0669 Orifice Fan Width Flow Rate Part No Orifice Size Fan Width Flow Rate Part No 0 071 1 80 8 8 5 200 213 5 41 20 5 GG0471 10 10 5 250 263 GG0571 12 13 300 325 GG0671 16 17 400 425 GG0871 28 29 700...

Страница 26: ...18 400 460 182821 0 023 0 584 8 10 200 250 182423 0 584 10 12 250 300 182523 12 14 300 350 182623 14 16 350 400 182723 16 18 400 460 182823 0 025 0 635 8 10 200 250 182425 0 635 10 12 250 300 182525 1...

Страница 27: ...outlet 107142 1 2 npt m x f inlet outlet In line Fluid Filter 210500 5000 psi 35 MPa 350 bar Maximum Working Pressure 100 mesh Fits onto the gun s fluid connector 1 4 18 npsm Includes the parts shown...

Страница 28: ...a new gun with a 6 ft 1 8 m 1 4 in 6 3 mm OD cylinder air line and a 019 tip These val ues will vary slightly with use and with variations in equipment Cylinder air pressure psi MPa bar Fluid pressur...

Страница 29: ...308813 29 Notes...

Страница 30: ...olds 241161 and 241162 8576A 5 23 in 139 7 mm 2 0 in 50 8 mm 3 86 in 98 0 mm 8581A 3 0 in 76 2 mm 2 125 in 54 mm 8722A 0 187 in 4 8 mm 0 805 in 20 5 mm 0 4 in 10 2 mm Two M5 x 0 8 x 0 25 in 6 3 mm hol...

Страница 31: ...1 9 mm 3 5 in 88 9 mm 2 25 in 57 2 mm TI1397A 1 25 in 32 mm 2 13 in 54 mm Two M5 x 0 8 ISO H holes 0 25 in 6 35 mm deep 0 4 in 10 2 mm 1 375 in 35 mm TI1397A 0 805 in 20 4 mm 0 92 in 23 37 mm 0 437 in...

Страница 32: ...ch of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or proper...