6

Battery Replacement

The computer display is powered by two 3-volt 

lithium batteries which may be replaced while the 

meter is installed. When batteries are removed or 

lose power, the batch and cumula tive totals and 

the field and factory calibrations are re tained.

(Battery) – Avoid mechanical or electrical 

abuse.  Batteries may explode or cause 

burns, if disassembled, crushed or exposed 

to fire or temperatures in excess of 212°F 

(100°C). Do not short circuit or install with 

incorrect polarity.  DO NOT INCINERATE.

Batteries should ONLY be replaced with 

P/N 113520-1 Kit (Includes two each 

P/N 902004-2 Batteries). Do not mix old 

with new. Do not use other brands or 

technologies.

Open battery cells should be disposed 

of in accordance with local regulations. 

Lithium batteries are best disposed of as a 

non-hazardous waste when fully or mostly 

discharged.  EPA does not list or exempt 

Lithium as a hazardous waste.  If waste 

lithium batteries are still fully charged 

or only partially discharged, they can be 

considered a reactive hazardous waste 

because of unconsumed lithium remaining 

in the battery.  Such batteries may qualify 

as “Universal Waste” in many jurisdictions 

within the U.S. and thus can be shipped for 

disposal or recycling in accordance with 

Universal Waste requirements.  

 

CAUTION

 

WARNING

If the display becomes dim, blank

 

or the low 

battery message appears (see below), replace 

the batteries as follows:

1.  Remove the four Phillips-head screws from 

the face of the meter and lift the faceplate 

from the turbine.

2.  Remove the old batteries and clean any 

corrosion from the terminals.

3.  Install new batteries. Make sure the positive 

post is in the correct position.

4.  When the batteries are replaced, the face-

plate will power ON. Check the display to 

ensure normal functions have resumed 

before assembling again.

5.  Reseat batteries, if necessary, and posi-

tion the faceplate on the turbine housing. 

To avoid moisture damage, make sure the 

seal is fully seated. Tighten the four screws 

on the faceplate.

SPECIFICATIONS 

Inlet and Outlet:

Spigot (Pipe) End Models:

TM050/TM050-P  ½ inch Schd. 80,

  

Spigot (Pipe)

TM075/TM075-P  ¾ inch Schd. 80,

  

Spigot (Pipe)

TM100/TM100-P  1 inch Schd. 80,

  

Spigot (Pipe)

TM150/TM150-P  1 ½ inch Schd. 80,

  

Spigot (Pipe)

TM200/TM200-P  2 inch Schd. 80,

  

Spigot (Pipe)

NPT Models:

TM050-N/TM050-N-P  ½ inch NPT

TM075-N/TM075-N-P  ¾ inch NPT

TM100-N/TM100-N-P  1 inch NPT

TM150-N/TM150-N-P  1 ½ inch NPT

TM200-N/TM200-N-P  2 inch NPT
BSP Models:

TM100-B/TM100-B-P  1 in. BSP

TM150-B/TM150-B-P  1 ½ in. BSP

TM200-B/TM200-B-P  2 in. BSP

Design Type:

  Turbine

Wetted Components:

Housing:  PVC

Journal Bearings:  Ceramic

Shaft:  Tungsten Carbide

Rotor and Supports:  PVDF

Retaining Washer:  Stainless Steel

Max. Working Pressure:

 

 

 

225 PSIG @ 73° F 

 

BSP: 150 PSIG @ 73° F

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание TM050

Страница 1: ...inches of some electric motors or other sources of electronic noise INSTALLATION Connections Install your meter in line either horizontally or vertically or at the end of the hose adjacent to the nozz...

Страница 2: ...curls can adversely affect accu racy Correct the problem prior to turbine installation NOTE Do not over tighten the flange bolts This may cause the gasket to be compressed into the flow stream and ma...

Страница 3: ...ule and lift the module from the turbine 2 To change terminal block connections loosen the appropriate screws Reconnect the wires in the proper positions andtighten the screws 3 Install the batteries...

Страница 4: ...eplaceable batteries When display becomes dim faded or the low battery message appears see below the batteries need to be replaced Reference the Maintenance Section for details Factory and Field Calib...

Страница 5: ...ct When satisfied with the value press both CALIBRATE and DIS PLAY buttons simultaneously CALEnd will be displayed and unit will go back to normal operation less the FAC factory calibration icon 4 All...

Страница 6: ...becomes dim blank or the low battery message appears see below replace the batteries as follows 1 Remove the four Phillips head screws from the face of the meter and lift the faceplate from the turbin...

Страница 7: ...ch 222 kg 381 kg 381 kg 1 inch 299 kg 626 kg 666 kg 2 inch 354 kg 807 kg 875 kg Dimensions cm W x H x L Without Fitting With NPT Fitting 5 3 x 6 4 x 10 9 5 3 x 6 9 x 15 2 5 3 x 6 9 x 11 2 5 3 x 7 3 x...

Отзывы: