2.  Meter an exact known volume into an ac-

curate container. For best results, meter with 

one continuous full stream.

3.  Check the volume against the display or 

recording equipment. If the amount metered 

is accurate, further calibration is not neces-

sary. If not, refer to the Calibration Section 

for further instructions.

OPERATION

Computer Display – 

Batch and Cumulative Totals

The computer maintains two totals. The Cumula-

tive Total provides continuous measurement and 

cannot be manually reset. The Batch Total can 

be reset to measure flow during a single use. 

The Cumulative Total is labeled TOTAL 1, Batch 

Total is labeled TOTAL 2 BATCH.
When the Cumulative Total reaches a display 

reading of 999,999 the computer will highlight 

an X10 icon. This indicates to the operator that 

a zero must be added to the 6 digits shown. 

When the next rollover occurs, the computer 

will highlight an X100 icon. This indicates to 

the operator that two zeros must be added to 

the 6 digits shown.
Press the DISPLAY button briefly to switch 

between the TOTAL 1, TOTAL 2 BATCH and 

FLOWRATE. Press DISPLAY briefly to display 

the TOTAL 2 BATCH. Hold the DISPLAY button 

for 3 seconds to reset the Batch Total to zero.
When fluid is flowing through the meter, a small 

propeller icon is highlighted.
NOTE:  Totalization counts total units without 

differentiating between gallons, litres or field 

calibrated units.

Flowrate Feature

To use this feature, press and release DISPLAY 

button until FLOWRATE icon appears. The 

factory set time base will be highlighted to the 

right of FLOWRATE (M = minutes, H = hours, 

D = days). When FLOWRATE is invoked, the 

display will be indicating rate of flow.

Activate the Meter

Computer is on continuously and always ready 

to perform. The computer is powered by field 

replaceable batteries. When display becomes 

dim, faded or the low battery message appears 

(see below), the batteries need to be replaced. 

Reference the Maintenance Section for details.

Factory and Field Calibration

All calibration information is visible to the user 

as icons on the top line of the display, above 

the numeric digits.
All units are configured with a “factory” calibra-

tion. Both gallons and litres are available (“GL” 

or “LT” will be displayed). While holding the 

CALIBRATE button, briefly press DISPLAY to 

toggle between gallons and litres. This factory 

calibration (indicated with FAC) is permanently 

programmed into the computer and is not user 

adjustable.
NOTE:  Your computer may have other units of 

measure programmed into it. If so, holding 

the CALIBRATE button and momentarily 

pressing the DISPLAY button will toggle 

through all factory set units. Other possible 

units are: IGL (imperial gallon), QT (quart), CF 

(cubic feet), CM (cubic meter), BL (42 gal. 

barrel), CC (cubic centimeter) or OZ (ounce).

Switching between different units will not corrupt 

the Total’s contents. For example, in GL mode, 

the computer totalizes 10.00 gallons, if the user 

switches to LT mode, the display will read 37.85 

litres (the same volume, different unit).
The “field” calibration may be set by the user, 

and can be changed or modified at any time 

using the calibration procedure described in the 

Calibration Section. Totals or flowrate derived 

from the field calibration are invoked when the 

FAC icon is no longer visible on the top line of 

the display.

CALIBRATION

Verify Accuracy Before  

Beginning Field Calibration

For the most accurate results, dispense at a 

flowrate which best simulates your actual oper-

ating conditions. Avoid “dribbling” more fluid or 

repeatedly starting and stopping the flow. This 

can result in less accurate calibrations.
Make sure you meet the meter’s minimum 

flowrate requirements:

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание TM050

Страница 1: ...inches of some electric motors or other sources of electronic noise INSTALLATION Connections Install your meter in line either horizontally or vertically or at the end of the hose adjacent to the nozz...

Страница 2: ...curls can adversely affect accu racy Correct the problem prior to turbine installation NOTE Do not over tighten the flange bolts This may cause the gasket to be compressed into the flow stream and ma...

Страница 3: ...ule and lift the module from the turbine 2 To change terminal block connections loosen the appropriate screws Reconnect the wires in the proper positions andtighten the screws 3 Install the batteries...

Страница 4: ...eplaceable batteries When display becomes dim faded or the low battery message appears see below the batteries need to be replaced Reference the Maintenance Section for details Factory and Field Calib...

Страница 5: ...ct When satisfied with the value press both CALIBRATE and DIS PLAY buttons simultaneously CALEnd will be displayed and unit will go back to normal operation less the FAC factory calibration icon 4 All...

Страница 6: ...becomes dim blank or the low battery message appears see below replace the batteries as follows 1 Remove the four Phillips head screws from the face of the meter and lift the faceplate from the turbin...

Страница 7: ...ch 222 kg 381 kg 381 kg 1 inch 299 kg 626 kg 666 kg 2 inch 354 kg 807 kg 875 kg Dimensions cm W x H x L Without Fitting With NPT Fitting 5 3 x 6 4 x 10 9 5 3 x 6 9 x 15 2 5 3 x 6 9 x 11 2 5 3 x 7 3 x...

Отзывы: