GENERAL INFORMATION

The purpose of this manual is to assist 
you in installing, operating and main-
taining your mechanical fuel meter� 
Please take a few moments to read 
these instructions before installing and 
operating your fuel meter� 

The MR 5-30 Mechanical Fuel Meter is 

designed for the field measurement of 

thin viscosity petroleum fuels only and 
intended for use with pump systems 
in the 5 to 30 GPM or 19 to 114  LPM  

flow    range  (not  intended  for  gravity 

flow systems). Using mechanical gears, 

these meters translate flow data from a 

nutating disc into calibrated units which 
are indicated on the face of the meter� 
This meter is factory calibrated for kero-

sene grade (JET A). Field calibration 

feature is available for other fluids, see 

Calibration section�

For ground-based refueling only. 
Do not use in or on the aircraft. 

 

Use this meter with aviation gasoline 
(AVGAS 100LL) and kerosene grade 
(JET A).

 
Do not use this equipment for dis-

pensing any fluids other than those 

for which it was designed. To do so 
may damage the meter and will void 
the warranty.

SAFETY INSTRUCTIONS

 

The following safety
alert symbols are used 
in this manual.

DA N G E R

DANGER indicates a hazardous 
situation which, if not avoided, will 
result in death or serious injury.

WARNING

WARNING indicates a hazardous 
situation which, if not avoided, could 
result in death or serious injury.

CAUTION

CAUTION indicates a hazardous 
situation which, if not avoided, may 
result in minor or moderate injury.

It is your responsibility to:

• 

know and follow applicable na-
tional, state and local safety codes 
pertaining to installing and operat-
ing electrical equipment for use 

with flammable liquids.

• 

know and follow all safety precau-
tions when handling petroleum 
fuels

• 

ensure that all equipment op-
erators have access to ade-
quate instructions concerning 
safe operation and maintenance� 

1� 

DA N G E R

 Observe precau-

tions against fire or explosion when 

dispensing fuel� Do not operate 
the meter in the presence of any 
source of ignition including run-
ning or hot engines, lighted ciga-
rettes, or gas or electric heaters� 

2� 

WARNING

  Any components 

such as hose, nozzle, or pump 
added to your meter must be 
statically grounded and approved 
for use with petroleum fuels� 

3� 

WARNING

  Avoid prolonged 

skin contact with petroleum fuels� 

Use  protective  goggles,  gloves, 

and aprons in case of accidental  
splashing  or  spillage�  Change 
saturated clothing and wash skin 
contact areas promptly with soap 
and water�

 

2

WARNING

Содержание MR 5-30

Страница 1: ...s on receiving your GPI MR5 30Meter Wearepleasedtoprovide you with a meter designed to give you maximum reliability and efficiency Ourbusinessisthedesignmanufacture and marketing of liquid handling agricultural andrecreationalproducts We succeedbecauseweprovidecustomers withinnovative reliable safe timely and competitively priced products We pride ourselvesinconductingourbusinesswith integrity and...

Страница 2: ... manual DA N G E R DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazardous situation which if not avoided may result in minor or moderate injury It is your responsibility to know and follow applicable na tional...

Страница 3: ... the two screws that hold the faceplate in place and remove faceplate Figure 1 3 Remove two screws to release the counter assembly Figure 2 4 Remove the bevel gear from the center of the coverplate Remove the eight pairs of nuts and bolts that hold the coverplate assembly in place 5 Now you can rotate the coverplate to the desired orientation Reassemble in reverse order making sure the O ring is f...

Страница 4: ... reset the Batch Total to zero by turning the knob Figure 3 The small display represents the Cumulative Total of all fuel deliveries and cannot be reset CALIBRATION The meter is accurately calibrated at the factory for use with kerosene grade JET A Due to differences in viscosity and flowrates the meter may require recalibration to measure other fuels or to adjust for inaccuracies 1 Purge air from...

Страница 5: ...ween coverplate Remove coverplate and inspect and housing for damaged missing or incorrectly seated seal Replace as required 3 Leakage at fittings Remove fittings and inspect for damaged missing or incorrectly seatedseals Replaceasrequired 4 Leakage at threads Remove meter and reseal all threaded connections with thread tape or pipe thread sealing compound approved for use with flammable liquids S...

Страница 6: ... and hardware 126530 02 Gallon Faceplate Kit includes faceplate decal and hardware 126530 03 Litre Faceplate Kit includes faceplate decal and hardware 126530 01 Bezel Kit includes hardware 126530 07 Knob Assembly Kit 126530 12 Fitting Kit for 3 4 inch NPT 2 Fittings 2 Fitting O Rings 1 strainer and hardware 126530 13 Fitting Kit for 3 4 inch BSPP 2 Fittings 2 Fitting O Rings 1 strainer and hardwar...

Страница 7: ...andling requirements you will need to follow covering the transportation and handling of fuel transfer equipment Before packing for shipment make sure the meter is thoroughly drained and free of fuel and vapors Kits and Accessories continued Kit No Part No Description Do not return meters or parts without specific authority from the GPI Customer Service Department Due to strict regulations governi...

Страница 8: ...f Manufacturer The warranty shall extend to the purchaser of this product and to any person to whom such product is transferred during the warranty period This warranty shall not apply if A the product has been altered or modified outside the warrantor s duly appointed representative B the product has been subjected to neglect misuse abuse or damage or has been installed or operated other than in ...

Отзывы: