ELECTRONIC MODULE

PROGRAMING DETAILS

c) To access the programs and settings, hold down the 

RESET

 button for 5 seconds

d) To scroll through the setting options press the

DISP

 button.

The electronic module has been set up as follows:-

totL 2

rAtE 3

diSP 4

CALI 5

CONF 6

dIA 7

2. TOTALS

3. FLOWRATE

4. DISPLAY

5. CALIBRATION

6. CONFIGURATION

7. DIAGNOSTICS

NOTE:

 Details for changing  individual options .

             For example to change the units setting on the batch total turn to item 2 - 21

21 change batch total (units)

23 change resetable accumulative total  (units)
24 change resetable accumulative  total (decimal point)

25 change non-resetable accumulative total (units)

26 change non-reset accumulative total (decimal point)

22 change batch total (decimal point)

27 change “K” factor

31 change flowrate (units)

32 change flowrate (decimal point)
33 change flowrate (time base setting)

34 set the amount of signal pulses to calculate flowrate

35 set minimum flow rate

41 set sleep mode

43 set sleep time

42 change display (wake up default setting )

51 calibration adjustment

6  configuration details

71 diagnostic mode

a) Ensure the meter is awake before trying to enter the programming mode.

b) If the meter goes into sleep mode during programming, it will automatically
    return to operating mode.

totL 2

Note:

 As the decimal point does not float we recommend that a maximum of 2 decimal

         places be used, see below for details.

Содержание LM50DB

Страница 1: ...er has incorporatedtheovalrotorprincipalintoitsdesign Thishas proven to be a highly reliable and highly accurate method of measuring flow providing exceptional repeatability and high accuracy GPI reco...

Страница 2: ...nic computer module is non repairable The meter will need to be replaced if found to be damaged or faulty 1 Remove the 8 x philips head screws 1 from the meter cover 2 Remove the meter cover 2 and o r...

Страница 3: ...oint 25 change non resetable accumulative total units 26 change non reset accumulative total decimal point 22 change batch total decimal point 27 change K factor 31 change flowrate units 32 change flo...

Страница 4: ...1 1 decimal place 27 K FACTOR kFac 27 normal setting is 112 00 pulses b Press RESET 7 times kFac 27 will appear c Press and hold down RESET for 2 seconds program will appear To change the K factor pr...

Страница 5: ...nds program will appear e Press RESET to select sleep setting no sleep sleep 5 f Press and hold down RESET until program disappears to accept setting f Press and hold down RESET until program disappea...

Страница 6: ...1 DIAGNOSTICS dIA 7 diagnostic mode b Press the DISP button 5 times to reach dIA 7 c Press RESET dIA 71 will appear d Press and hold down RESET for 2 seconds Program will appear then all the segments...

Страница 7: ...7 NOTES...

Страница 8: ...n d to th e p u r c h a s e r o f th is p r o d u c t a n d to a n y p e r s o n to w h o m s u c h p r o d u c t is tr a n s fe r r e d d u r in g th e w a r r a n ty p e r io d T h e w a r r a n ty...

Отзывы: