3
ELECTRONIC MODULE
PROGRAMING DETAILS
c) To access the programs and settings, hold down the
RESET
button for 5 seconds
d) To scroll through the setting options press the
DISP
button.
The electronic module has been set up as follows:-
totL 2
rAtE 3
diSP 4
CALI 5
CONF 6
dIA 7
2. TOTALS
3. FLOWRATE
4. DISPLAY
5. CALIBRATION
6. CONFIGURATION
7. DIAGNOSTICS
NOTE:
Details for changing individual options .
For example to change the units setting on the batch total turn to item 2 - 21
21 change batch total (units)
23 change resetable accumulative total (units)
24 change resetable accumulative total (decimal point)
25 change non-resetable accumulative total (units)
26 change non-reset accumulative total (decimal point)
22 change batch total (decimal point)
27 change “K” factor
31 change flowrate (units)
32 change flowrate (decimal point)
33 change flowrate (time base setting)
34 set the amount of signal pulses to calculate flowrate
35 set minimum flow rate
41 set sleep mode
43 set sleep time
42 change display (wake up default setting )
51 calibration adjustment
6 configuration details
71 diagnostic mode
a) Ensure the meter is awake before trying to enter the programming mode.
b) If the meter goes into sleep mode during programming, it will automatically
return to operating mode.
totL 2
Note:
As the decimal point does not float we recommend that a maximum of 2 decimal
places be used, see below for details.