3

Figure 1

5.  To prevent pressure buildup and possible leaks through 

the ball valve, make sure the tank is vented.

Installing Discharge Plumbing on 

Pump Outlet

1.  Install  a  90  degree  elbow  to  the  pump  outlet  using  oil 

resistant pipe sealant.

2.  Install  the  hose  and  ball  valve  using  oil  resistant  pipe 

sealant on the threads. Tighten securely.

Electrical Installation

Electrical wiring must be done by a licensed electrician. 

Shut off all power before connecting wires to motor. Failure 

to follow these wiring instructions may result in death or 

serious injury from shock, fire or explosion. 

115-volt AC Powered Pumps (Models L 5116 & L 5132):

This GPI Oil Pump is factory wired for 115-volt AC. Power to 

the unit should be supplied from a dedicated circuit breaker.
If AC extension cords are used, they must be capable of safely 

carrying the rated motor current. Use only heavy duty, 3-wire, 

grounded extension cords.
NOTE:    Many  building  codes  require  Ground  Fault  Circuit 

interrupt (GFCI) protection.

Motor Ratings (FLA):

 

115-volt AC:

 

 

1/2 HP, 1725 RPM – 7.5 amps

 

 

1 HP, 3450 RPM – 13 amps

 

12-volt DC:

 

 

1/2 HP, 1800 RPM – 40 amps

12-volt DC Powered Pumps (Model L 5016):

This  GPI  Oil  Pump  is  factory  wired  for  12-volt  DC.  Circuit 

must be protected with a 50 amp automotive-type fuse (not 

supplied).
The power cord is not supplied with the pump. GPI recom-

mends a minimum power cord of 10/3 AWG. Do not exceed 

15 feet of cord.

CAUTION

OPERATION

Do not operate pump dry.  Damage to pump could occur.

Before  first  usage,  pour  oil  into  pump  outlet  port  to  coat 
pumping element.

1.  Place ball valve into the receiving tank to be filled.
2.  Turn on the motor.
3.  Open the ball valve and fill the container to the desired 

level. If flow does not occur with 15 seconds, shut off motor 

and refer to the priming information in the Troubleshooting 

Section.

4.  Shut off the nozzle.

5.  Turn off the motor.

Motor Protector

The AC pumps contain thermal motor protection. If the pump 

overheats the unit will shutoff.
If the motor shuts off, follow these instructions:

Model L 5132:

 Turn off the switch. Allow the motor to cool 

before restarting.

Model L 5116:

 Turn off the switch. Allow the motor to cool. 

Push the button to manually reset the protector.

Model L 5016:

 The 12-volt model is protected by inline fuse 

(not supplied). If the motor shuts off, check the fuse.

Disconnect power and relieve pressure in the system by open-

ing the nozzle before servicing the pump.
This pump is designed for minimum maintenance. Motor bear-

ings are sealed and require no lubrication. Inspect the pump 

and components regularly for leaks and make sure the hose, 

ball valve and components are in good condition.
Use of the pump with unauthorized fluids will void the war-

ranty.
Remove and clean the strainer if low flow is noticed. To clean 

the strainer, remove the three screws on the strainer cover. 

Remove cover and pull out screen. Clean screen and reinstall. 

Care should be taken not to damage the O-ring.

MAINTENANCE

WARNING

Содержание L 5016

Страница 1: ...afety is important to us Also to assure the longest possible service life it is important that you follow the operation and maintenance procedures outlined in this manual We are proud to provide you w...

Страница 2: ...uredtopreventtipoverwhen full or empty All tanks must be properly vented Installing Pump to a Tank GPI pumps have a 2 in NPT connection that can be mounted directly to a 2 in female pipe thread on the...

Страница 3: ...ot exceed 15 feet of cord CAUTION OPERATION Do not operate pump dry Damage to pump could occur Before first usage pour oil into pump outlet port to coat pumping element 1 Place ball valve into the rec...

Страница 4: ...wear Inspect gerotor Replace if worn 7 Low voltage to motor Ensure power at motor is at proper voltage C MOTOR STALLS WHEN 1 Bypass valve is sticking Remove inspect bypass valve Clean if necessary VA...

Страница 5: ...5 VISCOSITY CHARTS...

Страница 6: ...e Cover 1 11 142014 01 Motor 115 VAC 1 2 HP 1725 RPM 1 12 142015 01 Motor 115 VAC 1 HP 3450 RPM 1 13 142016 01 Motor 12 VDC 1 2 HP 1800 RPM 1 14 142022 01 Inlet Base Assembly 1 15 142023 01 Poppet Plu...

Страница 7: ...mperature Maximum temperature is 140 F 60 C See Viscosity Chart for minimum temperature Electrical Specifications Input 12 volt DC 115 volt AC 115 volt AC Current Draw 40 amps 7 5 amps 13 amps Motor 1...

Страница 8: ...ed to neglect misuse abuse or damage or has been installed or operated other than in accordance with the manufacturer s operating instructions To make a claim against this warranty contact the GPI Cus...

Отзывы: