GPI GM005 Скачать руководство пользователя страница 6

Pulse

1 to 30/ 0.26 to 8

3 to 25/ 0.8 to 6.60

+/- 0.5%

1000 Centipoise

5500kPa/ 800 PSI/ 55 BAR

80°C/ 176°F
(S.S. Models 120°C/ 248°F)
Dual Reed Switches or Hall
Effect Sensor or combination
HE Sensor/Reed Switch**

112 / 224

* Unless High Viscosity Rotors are fitted. 

5

Meter Specifications

Meter Type

Flow Ranges

Litres/minute - US Gall/min

Above 5 Centipoise

Below 5 Centipoise

Accuracy of Reading

Maximum Viscosity*

Max. Operating Pressure

Max. Operating Temp.

Pulse Type

Pulses Per Litre/US Gallon

Meter Trouble Shooting

TROUBLE

Fluid will not flow through meter

Reduced flow through the meter

Meter reading inaccurate

Meter not giving a pulse signal

CAUSE

a]

Foreign matter blocking rotors

b]

Line strainer blocked

c]

Damaged rotors

d]

Meter connections over tightened

e]

Fluid is too viscous

a]

Strainer is partially blocked

b]

Fluid is too viscous

a]

Fluid flow rate is too high or too low

b]

Fluid is too viscous

c]

Excess wear caused by incorrect
installation

a]

Faulty hall effect sensor

b]

Faulty reed switch

c]

Magnets failed

REMEDY

a]

Dismantle meter, clean rotors
(Strainer must be fitted in line)

b]

Clean strainer

c]

Replace rotors (Strainer must be
fitted in line)

d]

Re-adjust connections

e]

See specifications for maximum
viscosity

a]

Clean strainer

b]

See specifications for maximum
viscosity

a]

See specifications for minimum and
maximum flow rates

b]

Bleed air from system

c]

Check meter body and rotors.
Replace as required. Refer to
installation instructions

a]

Replace PCB Board

b]

Replace PCB Board

c]

Replace magnets

Содержание GM005

Страница 1: ...MS345G 0603 0005 Positive Displacement Flowmeters GM005 series instruction manual GM005 Pulse Meter From serial No CXXXX...

Страница 2: ...cuit board containing either Reed switches or Hall Effect sensors A signal is generated which is then sent by the Pulse Circuit Board PCB to the relevant LC display or receiving instrument Operating P...

Страница 3: ...The register assembly may be orientated to suit the individual installation Note Incorrect installation can cause premature wear of meter components 7 Do not over tighten meter connections 8 It is im...

Страница 4: ...efer Fig 5 and check their operation by turning either of the rotors If the rotors are not in mesh correctly or do not move freely remove one of the rotors and replace correctly at 90o to the other ro...

Страница 5: ...1 u MS344 HES PCB Hall Effect Sensor 5 1 MS344 R HES PCB 1 Reed Switch 1 Hall Effect Sensor 6 2 MS284S PCB Board Screws 7 4 u MS346S Meter Cap Screws Standard 7 4 u MS350S Meter Cap Screws Stainless...

Страница 6: ...n matter blocking rotors b Line strainer blocked c Damaged rotors d Meter connections over tightened e Fluid is too viscous a Strainer is partially blocked b Fluid is too viscous a Fluid flow rate is...

Страница 7: ...facturer s operating instructions To make a claim against this warranty notice of claim must be given in writing to the company at its address below no later than 30 days after the expiration of the w...

Отзывы: