1]

it is recommended that when setting

up pipework for meter installations a

bypass line be included in the design.

This provides the facility for a meter

to be removed for maintenace

without interrupting production. (See

Fig.1)

2]

Use thread sealant on all pipe

threads.

3]

For pump applications ensure pipe

work has the appropriate working

pressure rating to match the pressure

output of the pump. See Meter

Specifications section for further

details.

4]

Install a wire mesh strainer (Y or

basket type 60 mesh as close as

possible to the inlet side of the meter.

5]

Ensure that the meter is installed so

that the flow of the liquid is in the

direction of the arrows embossed on

the meter body.

6]

The meter can be installed in any

orientation as long as the meter shafts

are in a horizontal plane. (Refer to

Fig.2 for correct installation) The

register assembly may be orientated

to suit the individual installation.

Note: Incorrect installation can cause

premature wear of meter components.

7]

Do not over tighten meter

connections.

8] It is important that after initial

installation you fill the line slowly,

high speed air purge could cause

damage to the rotors.

9]

Test the system for leaks.

10]

Check the strainer for swarf or

foreign material, after the first 200

litres check periodically,

particularly if the flow rate

decreases.

2

Installation

1

2

Bypass Line

Flow Outlet

Flow Inlet

Strainer

Do Not Install Meter This Way

Electrical Connections

Contact rating 15VA
Maximum Voltage 150VDC

Note:

Double rate pulse output not available

3

4

Reed/Hall combination
1 - Reed Switch
2 - Reed Switch
3 - HE Common -
4 - HE Signal
5 - HE

Hall/Hall Combination
1 - HE1
2 - HE1 Signal
3 - HE Common -
4 - HE2 Signal
5 - HE Ground

Hall Effect Voltage 4.5 to 24 VDC
Current Draw Minimum 4.6mA
Output NPN Open Collector 25mA

Reed Switch Connections

Hall Effect or Reed/Hall Sensor Connections

Содержание GM005

Страница 1: ...MS345G 0603 0005 Positive Displacement Flowmeters GM005 series instruction manual GM005 Pulse Meter From serial No CXXXX...

Страница 2: ...cuit board containing either Reed switches or Hall Effect sensors A signal is generated which is then sent by the Pulse Circuit Board PCB to the relevant LC display or receiving instrument Operating P...

Страница 3: ...The register assembly may be orientated to suit the individual installation Note Incorrect installation can cause premature wear of meter components 7 Do not over tighten meter connections 8 It is im...

Страница 4: ...efer Fig 5 and check their operation by turning either of the rotors If the rotors are not in mesh correctly or do not move freely remove one of the rotors and replace correctly at 90o to the other ro...

Страница 5: ...1 u MS344 HES PCB Hall Effect Sensor 5 1 MS344 R HES PCB 1 Reed Switch 1 Hall Effect Sensor 6 2 MS284S PCB Board Screws 7 4 u MS346S Meter Cap Screws Standard 7 4 u MS350S Meter Cap Screws Stainless...

Страница 6: ...n matter blocking rotors b Line strainer blocked c Damaged rotors d Meter connections over tightened e Fluid is too viscous a Strainer is partially blocked b Fluid is too viscous a Fluid flow rate is...

Страница 7: ...facturer s operating instructions To make a claim against this warranty notice of claim must be given in writing to the company at its address below no later than 30 days after the expiration of the w...

Отзывы: