GPI GM005 Скачать руководство пользователя страница 5

4

Meter Parts Listing

1

1

MS298B

Meter Body 1/2” BSP (Aluminium)

1

1

MS298N

Meter Body 1/2” NPT (Aluminium)

1

1

MS337B

Meter Body 1/2” BSP (Stainless Steel)

1

1

MS337N

Meter Body 1/2” NPT (Stainless Steel)

2

1

u

BS145S

“O” Ring (NBR)

2

1

u

BS145TES

“O” Ring (Teflon)

2

1

u

BS145VS

“O” Ring (Viton)

3

2

u

MS342S

Rotors PPS (Polyphenylene Sulfide Resins)

3

2

u

u

MS342-1S

Rotors (Stainless Steel)

3

2

u

MS342HS

High Viscosity Rotors (PPS)

3

2

u

MS342-1HS

High Viscosity Rotors (Stainless Steel)

4

1

MS297

Meter Cap (Aluminium)

4

1

MS338

Meter Cap (Stainless Steel)

5

1

u

MS344-RS

PCB (Standard Reed Switch)

5

1

u

MS344-HES

PCB (Hall Effect Sensor)

5

1

MS344-R/HES

PCB ( 1 Reed Switch & 1 Hall Effect Sensor)

6

2

MS284S

PCB Board Screws

7

4

u

MS346S

Meter Cap Screws (Standard)

7

4

u

MS350S

Meter Cap Screws (Stainless Steel)

8

1

u

MS340S

Pulser Cap Gasket

9

1

MS296

Pulser Cap (Aluminium) 20mm Conduit Thread

9

1

MS296N

Pulser Cap (Aluminum) 1/2” NPT Thread

9

1

MS339

Pulser Cap (Stainless Steel) 20mm Conduit Thread

9

1

MS339N

Pulser Cap (Stainless Steel) 1/2” NPT Thread

10

2

MS347S

Pulser Cap Screw (Stainless Steel)

11

1

MS37

Warning Label (Not Shown)

13

1

Customer to Specify

Legend Plate (Not Shown) inc. Hammer Screws

Item

No.

No.

Off.

Part or Set

(Order from this column only)

Part Description

Key:

u

Indicates recommended Spare Parts to stock

Bold text indicates Stainless Steel Model Parts

Rec.

Parts

Содержание GM005

Страница 1: ...MS345G 0603 0005 Positive Displacement Flowmeters GM005 series instruction manual GM005 Pulse Meter From serial No CXXXX...

Страница 2: ...cuit board containing either Reed switches or Hall Effect sensors A signal is generated which is then sent by the Pulse Circuit Board PCB to the relevant LC display or receiving instrument Operating P...

Страница 3: ...The register assembly may be orientated to suit the individual installation Note Incorrect installation can cause premature wear of meter components 7 Do not over tighten meter connections 8 It is im...

Страница 4: ...efer Fig 5 and check their operation by turning either of the rotors If the rotors are not in mesh correctly or do not move freely remove one of the rotors and replace correctly at 90o to the other ro...

Страница 5: ...1 u MS344 HES PCB Hall Effect Sensor 5 1 MS344 R HES PCB 1 Reed Switch 1 Hall Effect Sensor 6 2 MS284S PCB Board Screws 7 4 u MS346S Meter Cap Screws Standard 7 4 u MS350S Meter Cap Screws Stainless...

Страница 6: ...n matter blocking rotors b Line strainer blocked c Damaged rotors d Meter connections over tightened e Fluid is too viscous a Strainer is partially blocked b Fluid is too viscous a Fluid flow rate is...

Страница 7: ...facturer s operating instructions To make a claim against this warranty notice of claim must be given in writing to the company at its address below no later than 30 days after the expiration of the w...

Отзывы: