WINTERIZATION

 

 

Freezing of the water  heater and its plumbing  components  will  result  in severe damage that is 
not covered by warranty. For this reason it is not advisable to use the standard unit (Part# 1GWH) 
in the winter 

without  installing the Winter Use Device (See below for Winter Use Device 

option).

 

At the start of the winter  season or before traveling to a location where freezing conditions are 
likely the unit  must  be winterized. The very small amount of water present in the heat exchanger 
does not require the installation  of a bypass kit. 
Winterization can be accomplished using one of the two common  methods of winterization  used 
for  RV water systems: 

• 

Compressed  Air Method: 

Drain all water from the system opening one tap at a time 

and using compressed air to purge all remaining water. 

• 

RV Anti-freeze  Method: 

Follow the  recommendations  of the  Recreation Vehicle 

manufacturer  and fill  the system with  a non toxic anti-freeze. Make sure that the 
antifreeze flows from each tap to complete the process. 

PARTS BREAKDOWN

 

 

Item

 

Name

 

Part #

 

1

 

Burner Assembly 

1GWH1000 

2

 

Igniter/Flame sensor 

1GWH6310 

3

 

Heat Exchanger/Exhaust  Assembly 

1GWH2000/1GWH3000 

4

 

Blower  Motor  12  VDC 

1GWH6200 

5

 

Cold Water Inlet  Assembly 

1GWH5100 

6

 

Water Flow Switch 

1GWH7100 

7

 

Relay 

1GWH6800 

8

 

Hot Water Outlet Assembly 

1GWH5300 

9

 

P/T Relief Valve (1/2"NPT) 

1GWH7200 

10

 

Gas Valve Control 

1GWH6100 

11

 

Circuit Board and cover 

1GWH7300 

12

 

ECO (Limit Switch) 

1GWH6500 

13

 

Sail Switch 

1GWH6600 

14

 

Power/Mode  Switch (ON/OFF) 

1GWH6700 

15

 

Door Assembly 

1GWH4400 

16

 

Door Flange 

1GWH4300 

17

 

Flue Exhaust tube 

1GWH4700 

18

 

Winter  Use Device for  GSWH-1 (Aftermarket) 

1GWH9404 

19

 

Conversion Flange for Atwood 6 Gallon Polar White 

1GWHDA6 

20

 

Conversion Flange for Atwood or Suburban 10  Gallon Polar White 

1GWHDAS10 

Figure 10

 

Содержание GSWH-1

Страница 1: ...ed solely for use by trained personnel who perform service or repairs on the Model GSWH 1 Water Heater on behalf of a Girard Products LLC Authorized Service Center CSA Approved Girard Products LLC 136...

Страница 2: ...Equipment 6 5 Removing Controls Housing 7 6 Schematics and Diagrams a Ladder Diagram 8 b Wiring Diagram 9 7 Circuit Board Operation 10 8 Exploded View 12 9 Troubleshooting Guide 12 10 Circuit Board Tr...

Страница 3: ...ht of the Controls Housing Figure 1 Specifications The main performance specifications of the Model GSWH 1 are BTU HR 27 000 34 000 Fuel Propane LP Gas Inlet Pressure 10 5 WCI Min to 14 WCI Max Manifo...

Страница 4: ...properly installed in a Recreation Vehicle the Girard Tankless Water Heater is connected to The RV s cold water system with its water input from a pressurized 45 psi source such as a shore connection...

Страница 5: ...decrease the flow which results in hotter water to obtain the temperature desired Note although the Girard tankless water heater is instantaneous the water in the system pipes must be purged before th...

Страница 6: ...ls and or equipment are needed to service the Girard Tankless Water Heater The following equipment is commonly used for service and is readily available Be sure that all instruments are regularly cali...

Страница 7: ...owing equipment is commonly used for service and is readily available Be sure that all instruments are regularly calibrated To gain easy access to the serviceable components of the Water Heater you mu...

Страница 8: ...ing careful not to damage the tube Set aside for re assembly 5 Lean the Controls Housing to the right to slip it out of the wing nut s post and lift it to clear the bottom posts 6 Remove the assembly...

Страница 9: ...functional understanding of the electrical components and of the Circuit Board control functions Wiring Diagram Cold Hot Heat Exchanger GasValve 12VDC Red 12VDC Ground Black Ground Green Gas Valve Br...

Страница 10: ...rcuit Board indicating that there is sufficient air flow for combustion The circuit is now complete Try For Ignition TFI The Circuit Board is now ready to try for ignition and applies power to the gas...

Страница 11: ...the control will make two more attempts to relight and then go into lockout See Try for Ignition page 10 If flame is established Combustion Airflow Problems If the airflow signal is lost or the ECO o...

Страница 12: ...urner Auto Lo Thermostat Gas Control Valve Anti Freeze Thermostat Burner Manifold Power Switch Control Panel Housing Door Flange Door Figure 7 EXPLODED VIEW OF MODEL GSWH 1 AND MAJOR COMPONENTS IDENTI...

Страница 13: ...CO d Check Wiring to Board e Defective or Stuck Flow Switch Tap with Wrench If Problem not Solved Replace Flow Switch f Bad circuit board CONFIRM with Approved Board Tester such as Fenwal part 05 0802...

Страница 14: ...ester such as Fenwal part 05 080224 009 Replace 2 No Spark and No Gas Blower Operating a Low voltage Correct Power Supply Minimum 10 5 VDC b Check for Flow of Water c Check Relay d Check ECO e Check f...

Страница 15: ...lete Ignition of Burner Blades through Sight Hole Remove any Obstructions f Partially Obstructed Burner Manifold Clean Burner Orifices Replace if Necessary g Dirty Connector on Circuit Board Clean Edg...

Страница 16: ...ols remove any item present and wipe clean the bottom of the housing 5 Inspect the interior surface of the housing for any cracks or corroded areas that could allow penetration of gases into the inter...

Страница 17: ...ning water RV Anti freeze Method Follow the recommendations of the Recreation Vehicle manufacturer and fill the system with a non toxic anti freeze Make sure that the antifreeze flows from each tap to...

Страница 18: ...Switch 40 24 Cold Water Inlet Manifold Assembly 30 18 ECO 10 6 Sail Switch 20 12 Relay 30 18 Power On Off Switch 10 6 Mode Switch Hi Low Burner 10 6 Diagnostic LED 10 6 Winter Use Control Unit 30 18...

Отзывы: