22
When.you.log.in.to.configuration.mode.for.the.first.time,.it.is.recommended.that.you.set.a.new.
password.to.avoid.future.unsanctioned.access.to.the.terminal’s.options.
Go.to.the.“Options”.section,.choose.“Reset.options”.and.press......
Warning! The “Reset options” button in this menu resets all the terminal’s settings to factory
default settings, and removes all user and event data saved in the terminal’s memory.
To.change.the.terminal’s.network.settings,.go.to.the.“Network”.section.
Choose.the.“New.IP.address”.option.from.the.list.and.press......
Enter.the.required.IP.address.using.the.keypad.and.press......
Enter.the.required.network.mask.and.gateway.options.in.the.same.way.
Navigate.to.the.“Apply”.button.and.press......
After.this,.the.new.network.settings.will.go.into.effect.
The.device.is.ready.for.use..Further.configuration.of.the.device.should.be.carried.out.using.the.
BioSmart-Studio.or.BioSmart.Manager.programs.
The.BioSmart.PV-WTC.Operating.Manual.and.all.necessary.drivers.and.software.can.be.found.at.
the.address.
www.gp-systems.com
..in.the.“Technical.Support”.section.
10. ENSURING OF THE OPERATION
Go.to.the.“Info”.menu.and.confirm.that.the.physical.Ethernet.network.connection.is.established.
and.that.there.are.no.errors.in.the.device’s.operation.
If.the.device.is.connected.correctly.and.its.network.options.are.configured.correctly,.the.following.
parameters.should.be.displayed:
Next,.a.hardware.test.must.be.performed.on.the.terminal.
To.do.this,.press.the.“Menu”.button..A.prompt.will.appear.on.the.display.requesting.the.terminal’s.
configuration.password..To.log.in,.press. .
Select.“Self-diagnostics”.and.press. ..Wait.for.the.device’s.diagnostic.test.results.to.appear.on.
the.screen.
If.there.are.no.operational.errors.in.the.terminal,.the.message.“Success”.will.be.displayed.on.all.
the.tests..If.this.is.not.the.case,.you.must.contact.the.manufacturer.to.arrange.for.servicing.works.to.
be.carried.out..
Network.connection
. ..
Yes
IP.conflict
.
No
Hardware.errors
None