10
7.2.Description.of.connection.ports
A.view.of.the.terminal’s.circuit.board.is.shown.in.fig..3..The.circuit.board’s.contacts.are.described.
in.table.1.
Figure.3..Exterior.view.of.terminal’s.circuit.board
1...2..3..4...5...6..7..8.........9
11..12
10
Table 1. Circuit board connectors
No.
Label
Description
Connection purpose
1
REL
1st.relay.normally-open.contact.output.(DC.1A,.12V)
Actuator.control.input
2
REL
2nd.relay.normally-open.contact.output.(DC.1A,.12V) Actuator.power.supply.output
3
WG1
Wiegand.interface.DATA1.output
Wiegand.external.controller.interface.
DATA.1.intput
4
WG0
Wiegand.interface.DATA0.output
Wiegand.external.controller.interface.
DATA0.intput
5
IN+
+12V.output.for.discrete.input
Relay.control.button
6
IN
Discrete.input
Door.sensor.output,.relay.control.button
7
485-
-.interface.of.RS485.connection.with.BCR
-485.BCR.contact
8
485+
+.interface.of.RS485.connection.with.BCR
+485.BCR.contact
9
X3
Mini.USB.connector.for.terminal.configuration.using.
the.BioSmart.Manager.program.
Computer.USB.port
10 X4
RJ45(8P8C).port.for.Ethernet.network.connector
Ethernet.network.interface
11 GND
Power,.ground
Ground.of.12V.power.supply
12 +12.V
Power,.+12V
+12V.power.supply