Technical Data
9.1 Antenna
Table 23
Technical Data Antenna HG G-98780-A
Antenna HG G-98780-A
Casing
Refer to Figure 6 on page 15
Effective antenna area
refer to appendix, Section 10.1 on page 43
Power supply
24 V ±10 %, approx. 600 mA, approx. 2 A heating
Protection
–
Voltage supply (pin 1) 1 A slow-reacting
–
Heating (pin 3) 3 A slow-reacting
Operating temperature
-25 to +50° C
Warm-up time: Approx. 60 minutes at -20° C sur
-
rounding temp. (provided heater is in operation)
Automatic heater switch-on as soon as the tem
-
peratures are below 5° C
Mechanical stability
5 g 11 ms / 2 g 10 to 55 Hz
Weight
Approx. 6 kg
Installation regulations
refer to Figure 3 on page 11
Protection
IP 67
Connectors
HG G-98780ZA/WA
12-pin M3 screw-in plug
HG G-98780YA/XA
3 12-pin M23 built-in sockets
HG G-98780UA
Up to 3 cable tails (4 m)
With Transponder HG 70661
Reading distance
(distance transponder –
underside reading
antenna)
In direction of travel a max. of ±40 mm crosswise
to the center of the antenna:
50 to 90 mm
Nominal reading distance 75 mm
Nominal writing distance 75 mm
Position accuracy
refer to Section 10.2 on page 45
Max. pass-over speed
8 m/s
Output serial
(RS422 resp. RS232)
The output requires 9.6 or 19.2 kbaud. The tele
-
gram content is configurable. 3964R or „transpar
-
ent“ procedures are available.
Output CAN
(HG 98780ZA/WA)
According to ISO/DIS 11898 identifier, Data rate,
Basic/Extended CAN; configurable via ser. interf.
Profibus
(HG 98780YA/XA)
According to DIN 19245 / EN 50170
Autom. baud rate detection, supported baud
rates: 9,6 kBd, 19,2 kBd, 93,75 kBd, 187,5 kBd,
500 kBd, 1,5 MBd, 3 MBd, 6 MBd, 12 MBd
LED for Profibus status ’data exchange’
Output positioning pulse
20 mA current source, potentially separated