![Gotting HG G-98780-A Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/gotting/hg-g-98780-a/hg-g-98780-a_device-description_2247542022.webp)
Device Description HG G-98780-A | English, Revision 16 | Date: 15.07.2021
22
Chapter 5 – Components and Operation
5.2.6.1.2 List of commands
One command telegram always consists of four bytes, including the actual com
-
mand and the parameters. When using the procedure ‘transparent’ (also refer to Ap
-
pendix, section 10.7 on page 50) it is, in addition, necessary to transfer one start
character and a check sum (XOR operation of all bytes including the start character).
5 commands are defined:
Further information regarding command no. ...
1.
The monitor mode should not be used during normal operation (e. g. from an
PLC), as the following output is not according to a transparent or 3964R proto
-
col but only suitable for display on a VT52-terminal and used for the alteration
of parameters.
2.
An activated reference transponder is described by setting the corresponding
bit in the system status “0x0100“.
Please note that while the reference transponder is activated, the runway tran
-
sponders cannot be processed unambiguously, i.e. they are either oppressed or
their position is inaccurate.
3.
The successful deactivation of the reference transponder is described by delet
-
ing the “0x0100“ bit from the system status.
Table 10
List of System Commands
No. Description
Procedure
Start
Char.
Command
Byte
Parameter
Check
Sum
1
Switching into monitor
mode (described in sec
-
tion 6.2 „System moni
3964R
HEX
4D
16
4F
16
4E
16
49
16
ASCII
MO
NI
transparent
HEX 3D
16
4D
16
4F
16
4E
16
49
16
38
16
ASCII =
MO
NI
8
2
Switch off reference
transponder
3964R
HEX
52
16
54
16
30
16
30
16
ASCII
RT
00
transparent
HEX 3D
16
52
16
54
16
30
16
30
16
3B
16
ASCII =
RT
00
;
3
Switch on reference
transponder
3964R
HEX
52
16
54
16
31
16
31
16
ASCII
RT
11
transparent
HEX 3D
16
52
16
54
16
31
16
31
16
3B
16
ASCII =
RT
11
;
4
Supply of the 16 pro
-
grammable lower bits of
the transponder code
3964R
HEX
50
16
4C
16
Code in the format
tt
16
tt
16
For code „1234“ e. g.
12
16
34
16
ASCII
PL
transparent
HEX 3D
16
50
16
4C
16
07
16
ASCII =
PL
5
Supply of the 16 pro
-
grammable higher bits
of the transponder code
and start of the pro
-
gramming procedure
3964R
HEX
50
16
48
16
Code in the format
tt
16
tt
16
For code „1234“ e. g.
12
16
34
16
ASCII
PH
transparent
HEX 3D
16
50
16
48
16
03
16
ASCII =
PH