16
•
The product must be repaired by a professional maintenance staff
in case of any failure. Do not disassemble and overhaul it by
yourself.
•
Do not clean the glass of oven door with a rough detergent or sharp
metal scraper because it may lead to the smashing of the glass.
•
The power cord shall be unplugged when cleaning the cavity or
replacing the bulb.
GUIDELINE FOR TROUBLESHOOTING
The following table helps in solving problems that may arise while using
the device:
ABNORMAL
CONDITIONS
POSSIBLE CAUSES
SOLUTION
Device not
working
No power
Plug in power supply
Er1
Open circuit for top sensor
Stop the work, open the
oven door and
allow the
cavity to cool down for 10
minutes, and then restart it
or contact the after-sales
service.
Er2
Short circuit for top sensor
Stop the work, open the
oven door and
allow the
cavity to cool down for 10
minutes, and then restart it
or contact the after-sales
service.
Er3
Open circuit for down sensor
Stop the work, open the oven
door and allow the cavity to
cool down for 10 minutes, and
then restart it or contact the
after-sales service.
Er4
Short circuit for down sensor
Stop the work, open the oven
door and allow the cavity to
cool down for 10
minutes, and then restart it or
contact the after-sales service.
Er7
Open circuit for evaporating
heater sensor
Contact the after-sales
department for
repair.
Er8
Short circuit for evaporating
heater sensor
Contact the after-sales
department for repair.
No display on
the screen
1.
Check whether the power
supply plug is
plugged;
2.
Display panel in poor contact
1.
Re-energize;
2.
Contact the after-sales
department for repair
Содержание GPP-300