GMC-I Messtechnik GmbH
11
Note:
For temperature (
°
C), frequency (Hz), duty cycle (%) and
capacitance (F) measuring range is always Auto. No manual
range selection is possible.
4
Liquid Crystal Display (LCD)
4.1
Digital Display
The main digital display shows the measured value, decimal
point and sign. The selected measuring unit and function are
displayed.
When measuring DC quantities, a minus sign appears in front
of the digits, when the positive pole of the measured quantity is
applied to the „ “ input terminal.
„
OL
“ is displayed if the measuring range upper limit is
exceeded.
The digital display is updated three times per second for V, A,
Ω
, Cap., Freq. and duty cycle measurements.
4.2
Display with Backlight (Optional)
By pressing the
key, the backlight can be switched ON or
OFF to enable the user to take measurements in poor lighting
conditions.
AUTO
/
MAN
Function
Acknowledge-
ment
Display
Acoust.
Signal
brief
Manual mode
ON
:
utilized measuring range is fixed
1 x
brief
V : 400 mV
→
4 V
→
40 V
→
400 V
→
600 V
→
400 mV
→
4 V
→
...
V
/: 4 V
→
40 V
→
400 V
→
600 V
→
400 mV
→
...
mA : 40 mA
→
400 mA
→
40 mA
...
mA
/:40 mA
→
400 mA
→
40 mA
...
Ω
:
40 m
Ω →
400 m
Ω →
4 k
Ω →
40 k
Ω →
400 k
Ω
4 m
Ω →
40 m
Ω ...
1 x
long
Return to automatic range selection
AUTO
2 x