Serial
16 kB
Type
RS 232 C; RS 422; RS 485
or Current loop
Baudrate
110; 150; 300; 600; 1200;
2400; 4800;9600;19200;
38400
Data format
7 bit / 8 bit
1)
Parity bit
even, odd, mark, space, no
1)
Safety
acc. to EN 61010-1:2001
CAT III > 150 V
≤
300 V
pollution degree 2
DC
10 V ... 19 V
approx. 20 VA
2)
19 V ... 36 V
approx. 18 VA
2)
AC
85 V ... 265 V , 45 - 65 Hz,
approx. 15 W
switch-mode power supply
Storage temperature range
-20 °C to +60 °C
Operating temperature range 0 °C to +45 °C
Climate
relative humidity < 80 %
up to 31 °C
Protection type
acc. to EN 60529/VDE 0470
housing
IP 50
terminals
IP 00
Insulation group
C acc. to VDE 0110
Mech. strength
acc. to IEC 1010
EMC
Emission
EN 55011, Class A
EN 55022, Class B
Susceptibility
EN 61000-4-2 B
EN 61000-4-3 A
EN 61000-4-4 B
1)
See setting transmission parameters of the sender at page 9.
2)
Starting current approx. 1,2 A (10 V ... 19 V) or approx. 0,8 A
(19 V ... 36 V).
This value can be used to rate the external fuse.
Input buffer
Serial
Interface I
Voltage
supply
Ambient
conditions
Standards
CE