18
GOSSEN METRAWATT GMBH
7.4
Recording: Duration and Type – durA, CYCLE
•
Recording without Time Limits – durA
Key Sequence:
SEt
... ... durA
on
oFF
Settings:
oFF = time limiting disabled
Recording is continued until the memory is full. If the CYCLE function has been activated,
memory is overwritten in a cyclical fashion. See also drawing in chapter 7.3, page 16.
•
Time-Limited Recording – durA
Key Sequence:
SEt
... ... durA
ON
dd
hh:mm
Settings:
d = number of days (adjustable from 0 to 6)
hh = number of hours, mm = number of minutes
Recording is ended after the predetermined duration has expired.
See also drawing in chapter 7.3, page 16.
•
Cyclical Recording – CYCLE
Key Sequence:
SEt
rAtE ... CYCLE
OFF
on
Settings:
on = cyclical recording activated
When the memory is full, the oldest data are overwritten with new data (FIFO). See also
drawing in chapter 7.3, page 16.
•
Record Until Memory is Full – CYCLE
Key Sequence:
SEt
... ... CYCLE
on
OFF
Settings:
OFF = cyclical recording deactivated
When the memory full, data recording is ended. See also drawing in chapter 7.3, page 16.
7.5
Internal Time – timE
•
Set Current Weekday and Time (no date)
Key Sequence:
SEt
... ... tiME
dd
hh:mm
Settings:
dd = current weekday
hh:mm = current time in hours and minutes
Current weekday and time are set with this function.
7.6
Select Address and Modem Option – Addr, ModEM
Key Sequence:
SEt
... ... Addr
nn
ModEM
no
YES
Settings:
nn = 1 ... 15
ModEM = YES, if the adapter is
connected to the PC with a modem
If several memory adapters are connected to the PC, a separate address must be assigned
to each. Address number 1 should be assigned to the first adapter, address number 2 to the
second and so forth.
Note: