OM-07207
SUPER T SERIES
OPERATION
PAGE C - 1
OPERATION - SECTION C
OPERATION
Review all SAFETY information in Section A.
Follow the instructions on all tags, labels and
decals attached to the pump.
Do not operate an internal combustion
engine in an explosive atmosphere.
When operating an internal combustion
engine in an enclosed area, make sure
exhaust fumes are piped to the outside.
These fumes contain carbon monoxide,
a deadly gas that is colorless, tasteless
and odorless.
This pump is designed to handle
most
non‐volatile, non‐flammable liquids
containing specified entrained solids
and corrosives. Do not attempt to pump
volatile, corrosive, or flammable liquids
which may damage the pump or endan
ger personnel as a result of pump fail
ure.
Pump speed and operating condition
points must be within the continuous per
formance range shown on the perfor
mance curve on page E-1.
STARTING
Check the fuel level and oil levels in the engine, air
compressor, pump bearings and seal housing.
Make sure the pump is level. Lower the jack stands
and chock the wheels, if so equipped.
Make sure the pump is level. Lower jack
stands and chock the wheels, if so
equipped. Use caution when positioning
the skid‐mounted unit to prevent damage
to the fuel tank.
This pump is equipped with an automat
ic starting system, and is subject to au
tomatic restart. Keep hands and cloth
ing away from the unit to prevent injury
during automatic operation. Disconnect
the positive battery cable before per
forming any maintenance. Failure to do
so may result in serious personal injury.
Consult the engine operations manual before at
tempting to start the unit.
Consult the manual accompanying the engine
control box and start the pump.
PRIMING
Install the pump and piping as described in
IN
STALLATION
. Make sure that the piping connec
tions are tight, and that the pump is securely
mounted. Check that the pump is properly lubri
cated (see
LUBRICATION
in
MAINTENANCE
AND REPAIR
).
This pump is self‐priming, but the pump should
never be operated unless there is liquid in the
pump casing.
Never operate this pump unless there is
liquid in the pump casing. The pump will
not prime when dry. Extended operation of
a dry pump will destroy the seal assembly.