50
MDE-LEDI-NETWORK-TDS-4099V1.0
D. Restart button
The device can be remotely rebooted using the Restart button at the bottom of the
page. Then, the web page will not be accessible for approximately 1 min. until the unit
restarts.
5.2.10. UPDATE page
☛
WARNING: Depending on the update, the product may reset all settings
to factory default after updating the firmware. IP configuration will therefore
revert back to DHCP.
For each network port of the server, please follow the NETWORK MODULE UPDATE
PROCEDURE below.
Note: It is possible to launch the update of all modules at the same time to save up some
time (either automatically or by making use of the delay time).
Please read the “WARNINGS” note carefully.
►
Updating the firmware via File Transfer Protocol (FTP)
This method is usually used to solve issues or when the web interface is unavai-
lable.
The FTP interface must be activated in the device’s settings.
1 - Open a terminal (Start menu -> Execute -> "
cmd
")
2 - In the terminal, switch with the "
image.bin
" file to be sent to the product
using the "
cd <emplacement>
" command
3- Typey
"ftp <IP module address>",
ENTER
Login: “root”
Password: “gtmt”
4 - Type:
"
bin
", ENTER
"
put image.bin
", ENTER
"
quit
", ENTER