10
MDE-LEDI-NETWORK-TDS-4099V1.0
3.5. GENERAL FACTS ABOUT SYNCHRONIZATION
The synchronization is the process during which, a local clock (internal) will be tuned by
aligning on a distant clock (the reference).
A local clock works with a reference frequency signal generated by an oscillator. The LEDI
®
NETWORK TDS V1 uses a thermally compensated oscillator (TCXO).
►
The offset is the instantaneous difference between two clocks.
►
The drift is the late or advance that is taken by an oscillator as a consequence of its
imperfection. The better the oscillator, the lower the drift.
3.6. OPERATING MODES OF THE LEDI
®
NETWORK TDS V1
►
Not synchronized: no available time input. The server does not have the correct time
and does not deliver time on its outputs.
►
Autonomous: the server has been synchronized, but the input is no longer available. It
still has autonomy and keeps distributing time.
►
Free Running: The server has been manually forced to run in autonomous mode (time
may have been set by the user). It delivers time on its outputs.
►
Synchronized: The server is locked on a synchronization source. It delivers time on its
outputs.