background image

170687

Instructions for Use, Building- in and Connecting

13

Conversion to another type of gas

For the conversion procedure the appliance
need not be pulled out from its location.

Before starting to work on conversion,
disconnect the appliance from the mains and
shut the gas inlet valve.

Replace the existing nozzles of declared
nominal heat input with adequate nozzles for
the new type of gas (see table).

Adjust the nozzle for the minimum heat input
rate as long as it requires to arrive at the
minimum heat input; If the appliance needs to
be adjusted to liquid propane/butane gas, the
regulation valve for the minimum thermal load
must be tightened to the end.

Never unscrew nozzles for minimum heat input
rate for more than 1,5 turn.

Cooking burner (fig.1)

1

 Burner crown cap

2

Burner crown

   with burner cap
   support

3

Thermal probe

   (certain models
   only)

4

Ignition plug

5

 Nozzle

Setting elements

To provide access to the setting elements:

Remove the cooktop grid and burner crowns
with caps,

The setting elements of the double burner are
accessible behind the protective plate of the
main nozzle.

Remove the control knobs along with the seal
gaskets.

Gas faucet  (fig.2)

Minimum heat input setting screw

1

2

Содержание GCS64C

Страница 1: ...y not have Instructions for connecting the appliance The connections must be carried out in accordance with the instructions supplied with the appliance and in compliance with the recognized standards...

Страница 2: ...rsons with impaired physical motoric or mental capacity or persons with inadequate experience or knowledge do not use the appliance unless attended by a qualified person The same recommendation applie...

Страница 3: ...nt left 3 B Front right 1 A1 Rear right 1 75 A Total burner power kW 7 5 Gas specifications are indicated on the label adjacent to the rating plate Gas mains connection right ISO 7 R1 2 Category GB II...

Страница 4: ...s If you like your food to be crisp first set the burner to the maximum and continue cooking at minimum power Always provide adequate quantity of water when cooking in the pressure cooker Lack of wate...

Страница 5: ...lowest position Setting between the zero dot and the largest flame symbol is not recommended since the flame is not stable in that range and may easily get extinct In case the flame goes out repeat t...

Страница 6: ...ion of caps due to high temperatures is inevitable but it has no adversary effect on normal operation of burners Cleaning and maintenance of ceramic glass hob fig 1 fig 2 fig 3 fig 4 fig 5 Ceramic gla...

Страница 7: ...nly by qualified personnel or after sales service Note There are however some minor faults which may be easily removed by the user in accordance with the instructions that follow Important If the malf...

Страница 8: ...ppliance may be installed in any worktop with a thickness from 30 mm to 50 mm Installing the foam gasket Before inserting the appliance into the opening in the kitchen worktop the supplied foam gasket...

Страница 9: ...supply Mains voltage of the user 230 V must be verified with the measuring device Mains lead behind the cooker must be placed in such manner to avoid touching the back panel of the cooker because of t...

Страница 10: ...ith an exterior thread ISO 228 G1 2 or with the natural gas connection with a thread EN 10226 1 2 or EN ISO 228 1 Depending on the country specific connection regulations R1 2 The appliance is supplie...

Страница 11: ...um heat input If the appliance needs to be adjusted to liquid propane butane gas the regulation valve for the minimum thermal load must be tightened to the end Never unscrew nozzles for minimum heat i...

Страница 12: ...72 71 23 27 127 24 32 72 218 12 54 53 p 28 30 37 mbar Nozzle num 50 29 24 65 33 26 85 43 33 Wo 72 9 87 3 MJ m 3 Nozzle code 690780 690781 690782 Built in regulation knobs are intended for liquefied ga...

Отзывы: