12
Carbon filters can be used only when the hood is not connected to any ventilation duct.
Filters with active carbon can absorb odours until they are saturated. They cannot be washed or regenerated
and should be replaced at least every 2 months or more frequently in case of very intensive use.
2.
Replacement.
a)
Remove the metal grease filter,
b)
Remove the carbon filter situated on aluminium filter
c)
Install a new filter on the aluminium filter
The lighting system consists of two halogen lamps of 20 W power each.
To replace a light bulb proceed as follows:
d)
Using a flat tool or screwdriver prise the ring holding the halogen lamp glass (Fig. 8) and, holding it,
remove to the outside.
e)
Replace the bulb using a piece of cloth or paper for that purpose.
f)
Then reinstall the ring and the glass proceeding in reverse order.
Note: Make sure that you do not touch the halogen bulb to be installed with your
bare fingers!
The following shall be avoided during normal cleaning of the hood:
•
wet cloth or sponge and water jet,
•
solvents or alcohols which might dull lacquered surfaces,
•
caustic agents, particularly in regard to cleaning stainless steel elements,
•
hard, rough cloth
It is recommended to us moist cloth and neutral cleaning agents.
3.3.
Lighting
3.4.
Cleaning
Содержание DVG 8340 E
Страница 1: ...Kitchen extractor hood Kaminhaube Typ DVG 8340 E BEDIENUNGSANLEITUNG INSTRUCTIONS FOR USE ...
Страница 13: ...13 ...
Страница 14: ...14 Notes ...
Страница 15: ...15 Notes ...
Страница 16: ...16 ...