EN 20
Gas type P mBar
Modification
Wok
BG6xB/E
Wok
BG6xC/F
nozzle
nozzle
G20
20
-
142
150
Convert from G20 / 20 mbar to:
G20
13
Replace nozzle & no action by-pass
155
170
G30
28-30
Replace nozzle & screw in by-pass (see 3A)
94
100
(PL) G30
37
Replace nozzle & screw in by-pass (see 3A)
94
94
G31
37
Replace nozzle & screw in by-pass (see 3A)
94
100
G30
50
Replace nozzle & screw in by-pass (see 3A)
82
90
Gas type P mBar
Modification
Wok
BG6xB/E
Wok
BG6xC/F
nozzle
nozzle
G30
30
-
94
100
Convert from G30 / 30 mbar to:
G20
20
Replace nozzle & adjust bypass
(see 3C)
142
150
Power table (kW-g/h):
G20
13 mbar
G30-G31
28-30 mbar
PL G30
37 mba
G30
50 mbar
G150
8 mbar
Auxiliary burner
1.05
1.05 / 76
1.15 / 83
1.00 / 72
1.10
Semi-rapid burner
1.95
1.70 / 122
1.95 / 140
1.90 / 137
1.85
Rapid burner
3.10
3.00 / 216
3.30 / 238
3.00 / 216
3.00
Wok burner (BG6xB/E)
3.45
3.50 / 252
3.50 / 252
Wok burner (BG6xC/F)
4.00
3.90 / 281
3.90 / 281
4.00 / 288
Contents of conversion set
• Nozzles for burners and (if applicable) by-pass screws for gas taps.
• Data label with the modified gas specifications and setting.
Tools needed:
T1 Socket spanner (7 mm)
T2 Screw driver flat blade (4 mm)
T3 Nose pliers
T4 Open end spanner (7 mm)
T5 Leak test spray
CONVERSION INSTRUCTION