Special connections:
• Single phase connection (1 1N, 230 V~ / 50 Hz):
- The voltage between the phase and the zero is
230 V~. Fit a connecting bridge between connecting points
1-2 and 4-5. The group must have a fuse of at least 32 A.
The core diameter of the connecting should be at least
6 mm
2
.
Connection for hobs with 5 cooking zones:
• 3 phases with 1 zero connection (3 1N, 400 V~ / 50 Hz):
- The voltage between the phases and the zero is
230 V~. The voltage between the phases is 400 V~.
Fit a connecting bridge between connecting points 4-5.
The groups must have fuses of at least 16 A (3x). The core
diameter of the connecting cable must be at least 2.5 mm
2
.
The bridges on the connecting block can be used to create the
required connections, as indicated in these illustrations.
Check that the cabinet and the cut-out meet the dimension and
ventilation requirement
Threat the sawn ends of wooden or synthetic worktops with
sealing varnish if necessary, to prevent moisture causing the
worktop to swell.
Lay the hob upside down on the worktop.
Building in
31