background image

TAIYO ELECTRIC IND.CO.,LTD.

24

TAIYO ELECTRIC IND.CO.,LTD.

If you forget the code number, follow the procedure below to delete the code number 
and reset the key lock.

This procedure releases the key lock function which means that unauthorized persons 
can change temperature and/or parameter settings. Please keep this manual with 
authorized personnel only and in a safe place for future reference. 

Resetting the Code Number

1

4

Key Operation

TEMP Display

3

2

Press the 

key.

Press and hold the

and the

key simultaneously

for over 3 seconds.

Press the

keys so that the

present code number is displayed

Press the 

key.

Setting completed

Displays

alternately

Displays

alternately

Flashes 5 times.

Содержание RX-892AS

Страница 1: ...ded you will enjoy years of safe reliable service Thank you again for buying a goot soldering station WARNING Before using the soldering station read the Operation Manual Failure to follow the safety...

Страница 2: ...ry CAUTION Failure to obey a safety caution may result in a minor or moderate injury to yourself or to others Always follow the safety precautions to reduce the risk of electric shock fire or personal...

Страница 3: ...25 5 1 How to Change the Tip 26 5 2 How to change the Fuse 27 5 3 How to change the Filter 27 5 4 Housing Cleaning 28 5 5 How to Use and Maintain a Lead Free Soldering Iron 28 6 Troubleshooting 29 7 R...

Страница 4: ...release PAT Sleep mode can be exited by touching touch ing the wet sponge with the tip to cause tem perature fluctuation Effective when sleep setting temperature is greater than or equal to 100 C 7 Al...

Страница 5: ...ms are missing or damaged please contact your goot distributor Please store the packaging for future shipment or repair 2 2 Unpacking For how to use please see p 32 Control Unit Operation Manual Repla...

Страница 6: ...xing the tip If you do not perform this operation a measurement error occurs between the tip temperature and the set temperature CAUTION Operation Panel Filter Output Terminal for Soldering Unit Power...

Страница 7: ...shes when the tip temperature is out of the upper and lower temperature limits 5 KEY LOCK lamp Flashes while setting the Key Lock function Lights up when the Key Lock mode is set 6 KEY LOCK key Used t...

Страница 8: ...be soldered and melted solder get very hot Please be sure to wear proper apparel safety glass and gloves to prevent injury and property damage Do not wear unsuitable apparel for operation 5 CONNECT TO...

Страница 9: ...not used the plastic parts adapter ring and or soldering unit housing of the soldering iron unit could be damaged Position the soldering iron stand on a flat work surface bench 9 CONCERNING THE TIP A...

Страница 10: ...If the set temperature is set at 200 C 392 F the sleep temperature must be 150 C 302 F or lower 4 1 Changing the Set Temperature Displays flashes Refer to the Parameters table on page 31 for the expla...

Страница 11: ...the Tip Temperature Displays alternately Tip No List Press the key so that the tip Setting completed Press and hold the key for over L2 is displayed Displays alternately 3 seconds continuously Press a...

Страница 12: ...to contact with the RX 892AS soldering tip the metallic parts in the thermometer conduct heat which transfers away from the RX 892AS tip This results in the thermometer indicating a slightly lower tem...

Страница 13: ...e key for over 3 seconds continuously changes to 150 While setting the sleep function the sleep lamp will flash The flashing of the sleep lamp will become faster 30 seconds before entering Sleep mode...

Страница 14: ...rn off Set to 5 minutes before shipping Example Changing the sleep start time from 5 to 10 minutes Displays alternately Displays alternately Displays alternately Returns to the set temperature display...

Страница 15: ...e key for over 3 seconds continuously Displays alternately Displays alternately Displays alternately NOTE If the sleep sensitivity value DIF is set too high there is a possibility that the sleep funct...

Страница 16: ...P Display 3 When the SUT Shutdown Start Time value is set to 0 the shutdown function is OFF When the unit enters shutdown the Sdn and the temperature are displayed alternately After the temperature dr...

Страница 17: ...nd hold the key for over 3 seconds continuously Setting completed Returns to the set temperature display Press the Press the key 6 times to display At key Setting the soldering start time Tip temperat...

Страница 18: ...emperature Limit Upper Temperature Limit This function indicates to the operator with the sound of the alarm when the tip temperature goes past the set parameter The illustration on the right shows wh...

Страница 19: ...her than the set temperature depending on the tip type or the kind of work Overshoot Overshoot can be controlled by setting the parameters 4 Press down the SET key for over 3 seconds 3 Press the UP ke...

Страница 20: ...eration TEMP Display 4 9 Setting the Alarm Sound 3 Setting completed Returns to the set temperature display Press and hold the key for over 3 seconds continuously Press the key ten times Press the key...

Страница 21: ...peration TEMP Display 3 Press and hold the key for over 3 seconds continuously Displays alternately Press the key to change the format to F Fahrenheit F Press the key to change the format to C Celsius...

Страница 22: ...sing any three digit number from 001 to 999 l When the code number is set correctly the number will flash 5 times l If an incorrect code number is input the display will show NG and return to the init...

Страница 23: ...ress the key Press and hold the Example When changing the code number from 123 to 234 for over 3 seconds continuously Press the keys so that the present code number is displayed Press the key Input th...

Страница 24: ...ge temperature and or parameter settings Please keep this manual with authorized personnel only and in a safe place for future reference Resetting the Code Number 1 4 Key Operation TEMP Display 3 2 Pr...

Страница 25: ...rsonnel only and in a safe place for future reference How to Restore Default Settings Setting completed The preset temperature is displayed Though the key lock can be released by doing the procedure s...

Страница 26: ...the old tip 3 Insert a new tip aligned with the slit on the flange Push the tip as far as it will go and fix it securely with the tip fixing screw 5 1 How to Change the Tip NOTE When changing to a dif...

Страница 27: ...to remove it A spare fuse is stored on the other side of the fuse box Therefore turn the fuse box over or to the side to replace the fuse 5 2 How to Change the Fuse Pull out with a slotted screwdrive...

Страница 28: ...ompleted tin the tip with solder before turning the power off This protects the tip from oxidation when it starts heating up the next time it is in use A lead free soldering iron is more susceptible t...

Страница 29: ...does not go ON Check that the power cord is plugged in Check that the fuse is not blown The soldering iron tip does not heat up Check that the heater is not damaged Error message Cause Countermeasure...

Страница 30: ...tand ST 29 For RX 892AS 4 Sponge ST 53SP For ST 22 5 Brass Wool ST 40BW Cleaner For ST 22 2pcs set RX 89HRT series For replacement parts contact a goot distributor ST 53SP ST 40BW RX 89HRT 10D RX 89HR...

Страница 31: ...emperature Calibration cAL C F 50 to 50 90 to 90 0 Sleep Set Temp SSt C F 0 to Pt 50 32 to Pt 90 200 Sleep Timer ct Minute 0 00 to 999 5 Sleep Sensitivity diF C F 0 to 20 0 0 to 36 0 2 0 Shutdown Star...

Страница 32: ...revent fire or personal injury be sure that the stand has cooled sufficiently before storing it Rub the soldering iron tip on the moistened sponge Use the hole of the sponge for better cleaning Altern...

Страница 33: ...TAIYO ELECTRIC IND CO LTD 33...

Страница 34: ...TAIYO ELECTRIC IND CO LTD 34...

Страница 35: ...TAIYO ELECTRIC IND CO LTD 35...

Страница 36: ...RIES TAIYO ELECTRIC IND CO LTD Customer service Contact your nearest distributor goot is registered trade mark of TAIYO ELECTRIC IND CO LTD Printed in Japan JANUARY 2017 A1290AY00 AOB HomePage www goo...

Отзывы: