3.3 SEC1000S Installation
3.3.1 Selecting the installation location
The following must be considered when selecting the best location for an SEC1000S.
• The mount and installation method must be appropriate for the SEC1000S’s weight and
dimensions.
• Install on a sturdy surface.
• The installation location must be well ventilated.
• SEC1000S can be placed horizontally or installed vertically.
• The SEC1000S must be installed vertical or with a backward tilt less 15°.No sidwways tilt is
allowed.The connection area must point downwards.Refer to Figure 3.3.1-1.
• To allow dissipation of heat,and for convenience of dismantling,clearances around the
SEC1000S must be no less than the values, refer to figure3.3.1-2.
≤15°
Tubular terminal×6
O type terminal×8
Short wire×3
Screw×1
Tubular terminal×8
Ribbon×5
1 to 2 Wire Harness×5
Fireproofing mud×1
Back hang×1