background image

01

SEC1000S of Jiangsu GoodWe Power Supply Technology Co.,Ltd (hereinafter referred to as 

GoodWe) has been designed and tested strictly according to the international safety regulation.

As electrical and electric equipment,Safety Regulation shall be followed during installation and 

maintenance.Improper operation may bring severe damage to the operator,the third party and 

other properties.

•  Installation.maintenance of SEC1000S must be performed by qualified personnel.in compliance 

with local electrical standards. regulations and the requirements of local power authorities. 

•  To avoid electric shock,make sure the connection between SEC1000S and AC output of inverter. 

SEC1000S and Grid, is disconnected before performing any installation or maintenance.

•  When in operation,users should not touch any of the electrical parts of SEC1000S ,like internal 

components.cables, to  avoid electic shock.

•  All electrical installations must comply with local electrical standards and obtain permission from 

local power authorities before SEC1000S can be connected to the grid by professionals.

•  Before replacing any internal components of SEC1000S, the connection between the inverter 

and SEC1000S,the power grid and SEC1000S must be disconnected, and the newly replaced 

components must meet the requirements of SEC1000S. Otherwise,  GoodWe will not assume the 

responsibility and quality assurance for the personal harm.

•  Make sure that the AC input voltage and input current match the rated voltage and current of 

SEC1000S, otherwise the components will be damaged or cannot work properly,and GoodWe will 

not assume the responsibility and quality assurance for this case.

•  There are lightning protection modules inside.Make sure to connect the internal PE with the 

ground when intalling SEC1000S.

•  When in operation, do not plug or unplug cables of SEC1000S.

•  SEC1000S must be Installed out of reach of children.

•  Appropriate antistatic measures should be taken.

•  SEC1000S supports the three-phase four-wire grid structure only.

•  Can only be used in spontaneous self-use mode.

2 Safety and Warning

1 Symbols

Keep Dry – The package/product must be protected 

from excessive humidity and must accordingly be 

stored under cover.

Caution! - Failure to observe a warning 

indicated in this manual may result in 

minor or moderate injury.

This  side  up  -  The  package  must  always  be 

transported, handled and stored in such a way 

that the arrows always point upwards.

The  package/product  should  be 

handled  carefully  and  never  be 

tipped over or slung.

Components of the product can be 

recycled.

Danger of high voltage and electric 

shock!

Product should not be disposed as 

normal house hold waste.

No  more  than  six  (6)  identical 

packages be stacked on each other.

CE Mark

Содержание SEC1000S

Страница 1: ...SEC1000S USER MANUAL Smart Energy Controller...

Страница 2: ...bols 2 Safety and Warning 3 Mounting 4 Troubleshooting 5 Technology parameter 6 Relevant Certification 01 01 02 3 1 Mounting Instruction 3 2 Overview and Packaging 3 3 Inverter Installation 02 03 10 1...

Страница 3: ...ponents must meet the requirements of SEC1000S Otherwise GoodWe will not assume the responsibility and quality assurance for the personal harm Make sure that the AC input voltage and input current mat...

Страница 4: ...m gas and dust sufficient to corrode metals and destroy insulation SEC1000S parameters and warning signs must be clearly visible after installation SEC1000S should be installed without sunshine rain a...

Страница 5: ...ilated SEC1000S can be placed horizontally or installed vertically The SEC1000S must be installed vertical or with a backward tilt less 15 No sidwways tilt is allowed The connection area must point do...

Страница 6: ...3 Hole size Upward 200mm Downward 500mm Front 500mm Both sides 200mm 200mm 200mm 200mm 1 Drill holes on the wall 8mm in diameter and 45mm deep Refer to Figure 3 3 2 1 2 Fixthewallmountingbracketonthe...

Страница 7: ...ter No more than 25 mm B Cross Sectional Area of Copper Wire R ecommend AWG11 AWG13 C Wire Length About 45 mm D Length of Bare Copper Wire About 12mm 10mm for PE NO Range of current tested Content Rem...

Страница 8: ...ng use the fire proof mud to seal the port to ensure its protective performance Descriptions of internal communication ports of SEC1000S are as following Note The system supports up to 10 inverters pl...

Страница 9: ...ery cable AC cable backup side Back Up Loads Back Up Loads Back Up Loads Back Up Loads Back Up Loads Back Up Loads Back Up Loads Note No separate Smart Meter is required in inverter paralleling system...

Страница 10: ...dynamic IP mode he she only needs to connect the SEC1000S NET port to the Router LAN port with the network cable to connect to the network namely plug and play 2 If the user has a static IP it is nec...

Страница 11: ...nnection such as output active power output current and output voltage 3 3 5 2 PV Master configuration for paralleling application inverter You should set communication address for every inverter in t...

Страница 12: ...the short cable 5 Technology parameter 6 Relevant Certification Name SEC1000S Smart Energy Controller 1000S Technology parameter Input voltage range Phase voltage AC60V 280V Line voltage AC100V 480V I...

Страница 13: ...90 Zijin Rd New Distric Suzhou 215011 China T 400 998 1212 service chn goodwe com cn www goodwe com cn service au goodwe com cn www goodwe com cn service nl goodwe com cn www goodwe com cn enquiries...

Отзывы: