background image

GVC-1502-VAC 0920

5

•   In the event of breakdown or malfunction, switch off the GVC-1502-VAC and 

contact Goodway Technologies Corp. Customer Service Department.

•   Electrical appliances and fittings (TV, radio, lights, etc,) should never be 

cleaned with steam, even when not connected to a power supply. Exercise 

extreme caution when cleaning fixed electrical plant equipment; if in any doubt 

contact the relevant suppliers.

•   Do not put any detergent or other chemical substances (especially perfumed) 

in the water canister, as noxious gases can arise due to the high temperature.

•   Both main ‘on/off’ and pistol-grip switch 

must be off

 (‘OFF’) when connecting 

steam hose to the GVC-1502-VAC.

•   Ensure that the accessories are securely connected into the pistol-grip, by 

pulling both parts against each other to ensure a tight fit.

•   Exercise care when accessing internal components. For instance, steam-

associated components (e.g. drain screw) get 

very hot

 during operation and 

cools down very slowly after use

.

•   Do not use on or near 

heat sensitive materials

; this may 

damage

  

such materials!!

•   If you are unsure whether the material you want to clean is suitable for dry 

vapor steam cleaning, check first with a trial application on a small unobtrusive 

piece of the same material.

•   Do not use the small round metal brush on scratch-sensitive materials.
•   Exercise utmost care when cleaning windows or glass surfaces in low 

temperatures; warm the surfaces with steam beforehand to reduce the 

possibility of damage and injury.

• 

 The 

GVC-1502-VAC

 must never be immersed in water. Failure to comply with 

this warning will ENDANGER LIFE.

•   Always store the GVC-1502-VAC in a safe, dry and 

frost-free

 place. Frozen 

components can fail. Exercise care when storing directly after use as residual 

heat remains for some time.

•   For the GVC-1502-VAC to work efficiently the ambient temperature should be 

between 50°F (10°C) and 104°F (40°C) with humidity lower than 90%.

NOTE:

 Deionized and distilled water should never be used in the GVC-1502-VAC.

POWER CONNECTIONS

The GVC-1502-VAC is supplied with 13 feet (4 m) of cable and has a 15A three  

pin plug.
Ensure voltage between machine and supply match.

Содержание GVC-1502-VAC

Страница 1: ...GVC 1502 VAC Professional Steam Cleaner Operating and Maintenance Instructions Read before operating...

Страница 2: ...u in the future As with all Goodway products you can be assured that the finest quality components and workmanship have gone into this machine Please take a few minutes to read the following Operating...

Страница 3: ...trols before unplugging the power cord 10 When unplugging the power cord grasp the plug not the cord 11 Do not use the machine if it has a damaged cord or plug 12 If the machine does not operate prope...

Страница 4: ...condition check for visible signs of damage and do not use if damaged or faulty Never pull at the power supply cord and never allow it to rub against sharp edges or get caught between doors or drawer...

Страница 5: ...y after use Do not use on or near heat sensitive materials this may damage such materials If you are unsure whether the material you want to clean is suitable for dry vapor steam cleaning check first...

Страница 6: ...is properly grounded If the tools should electrically malfunction or break down grounding provides a low resistance path to carry electricity away from the user Boiler on off switch 93 S02181 On Off M...

Страница 7: ...lug unit into appropriate supply 4 Turn main switch ON to start the machine The ON OFF indicator light will illuminate 5 The green light flashing indicate that boiler is being filled with water Wait u...

Страница 8: ...cator light come on close the filler cap VACUUM MODELS ONLY The pistol grip and extension tubes have double locking clips Insert the selected accessory fully into the locking clip rotate it anticlockw...

Страница 9: ...tank and remove the lid Use fresh tap water to rinse out the waste water tank and the tap Remove any items from inside the tank that are likely to cause a blockage Replace the waste tank and refit the...

Страница 10: ...1 93 A00063 12 30 cm Floor Tool 93 A00066 Replace Squeegee 1 93 A00077 10 25 cm Squeegee Tool 1 93 A00078 6 15 cm Hand Tool 93 A00080 Replacement Squeegee 93 A00079 Replacement Brush Insert 1 93 A0015...

Страница 11: ...GVC 1502 VAC 0920 11 NOTES...

Страница 12: ...USA Effective date September 28 2020 Goodway is a Trademark of Crossford International Goodway reserves the right to improve products contact the factory for the latest configuration and uses Provide...

Отзывы: