42
GME8
B
LOWER
P
ERFORMANCE
D
ATA
Tons AC
at 0.5"
0.6
0.7
0.8
ESP
CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM CFM CFM
T1 - YELLOW
1.5
875
59
793
65
736
70
674
77
592
88
556
509
460
T2 - RED
2.0
1032
50
965
54
914
57
861
60
810
64
756
712
659
T3 - ORANGE
2.5
1217
43
1153
45
1098
47
1051
49
1009
51
964
918
877
T4 - BLUE
3.0
1365
38
1313
39
1268
41
1221
42
1172
44
1129
1086 1054
T5 - BLACK
3.5
1549
33
1505
34
1460
36
1420
37
1378
38
1350
1305 1268
T1 - YELLOW
2.5
1268
53
1198
56
1151
58
1092
61
1041
64
988
932
883
T2 - RED
3.0
1362
49
1305
51
1261
53
1212
55
1170
57
1121
1074 1021
T3 - ORANGE
3.5
1576
42
1519
44
1473
45
1426
47
1398
48
1341
1290 1252
T4 - BLUE
4.0
1755
38
1711
39
1657
40
1627
41
1579
42
1548
1502 1463
T5 - BLACK
5.0
2183
31
2128
31
2094
32
2060
32
2014
33
1992
1944 1847
T1 - YELLOW
3.0
1466
58
1415
60
1357
63
1306
65
1248
68
1202
1144 1088
T2 - RED
3.5
1642
52
1596
53
1552
55
1499
57
1449
59
1388
1352 1306
T3 - ORANGE
4.0
1750
49
1750
49
1707
50
1667
51
1610
53
1574
1531 1486
T4 - BLUE
4.0
1870
46
1805
47
1782
48
1737
49
1701
50
1656
1606 1571
T5 - BLACK
5.0
2297
37
2297
37
2224
38
2106
40
2014
42
1896
1813 1669
Notes:
• Temperature rise data is based on 2nd-stage heat. First-stage heat is 75% of rise indicated above.
• INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
• This chart is for information only. For satisfactory operation, external static pressure
should
not exceed value shown on the rating plate.
• The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same
temperature rise at a particular CFM, while ESP at the CFM will be lower.
• Factory Motor Speed Setting: T1 = 1st Stage Ht, T2 = 2nd Stage Ht, T5 = Cooling.
GME81155CXC*
• CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two
return filters, this chart assumes both filters are installed.
• All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling and heating speed as needed.
• For most jobs, about 375 - 400 CFM per ton when cooling is desirable.
(CFM & Temperature Rise vs. External Static Pressure)
0.1
0.2
0.3
0.4
0.5
Model
Heating Speed
As Shipped
Motor Speed
EXTERNAL STATIC PRESSURE (Inches Water Column)
GME80703BXC*
GME80905CXC*
(
)