SUPPLY

12" X 17"

RETURN

11" X 25"

H

oRIZontal

 d

IScHaRGE

 d

Uct

 c

onnEctIonS

RIGGING DETAILS

WARNING

t

o

 

PREvEnt

 

PRoPERty

 

daMaGE

tHE

 

UnIt

 

SHoUld

 

REMaIn

 

In

 

an

 

UPRIGHt

 

PoSItIon

 

dURInG

 

all

 

RIGGInG

 

and

 

MovInG

 

oPERatIonS

. t

o

 

facIlItatE

 

lIftInG

 

and

 

MovInG

 

WHEn

 

a

 

cRanE

 

IS

 

USEd

PlacE

 

tHE

 

UnIt

 

In

 

an

 

adEqUatE

 

cablE

 

SlInG

CAUTION

I

f

 

UnItS

 

aRE

 

lIftEd

 

tWo

 

at

 

a

 

tIME

tHE

 

foRk

 

HolES

 

on

 

tHE

 

condEnSER

 

End

 

of

 

tHE

 

UnIt

 

MUSt

 

not

 

bE

 

USEd

. M

InIMUM

 

foRk

 

lEnGtH

 

IS

 42” 

to

 

PREvEnt

 

daMaGE

 

to

 

tHE

 

UnIt

HoWEvER

, 48” 

IS

 

REcoMMEndEd

P

RovISIonS

 

foR

 

foRkS

 

HavE

 

bEEn

 

InclUdEd

 

In

 

tHE

 

UnIt

 

baSE

 

fRaME

.  n

o

 

otHER

 

foRk

 

locatIonS

 

aRE

 

aPPRovEd

.

WARNING

t

o

 

PREvEnt

 

PoSSIblE

 

EqUIPMEnt

 

daMaGE

PRoPERty

 

daMaGE

PERSonal

 

InjURy

 

oR

 

dEatH

tHE

 

folloWInG

 

bUllEt

 

PoIntS

 

MUSt

 

bE

 

obSERvEd

 

WHEn

 

InStallInG

 

tHE

 

UnIt

•   Unit must be lifted by the four lifting holes located at 

the base frame corners.

•   Lifting cables should be attached to the unit with 

shackles.

•   The distance between the crane hook and the top of 

the unit must not be less than 60”.

•   Two spreader bars must span over the unit to prevent 

damage to the cabinet by the lift cables.  Spreader 

bars must be of sufficient length so that cables do 

not come in contact with the unit during transport.  

Remove wood struts mounted beneath unit base 

frame before setting unit on roof curb.  These struts  

are intended to protect unit base frame from fork lift 

damage.  Removal is accomplished by extracting the 

sheet metal retainers and pulling the struts through 

the base of the unit.  Refer to rigging label on the unit. 

I

MPoRtant

: I

f

 

USInG

 

bottoM

 

dIScHaRGE

 

WItH

 

Roof

 

cURb

dUctWoRk

 

SHoUld

 

bE

 

attacHEd

 

to

 

tHE

 

cURb

 

PRIoR

 

to

 

InStallInG

 

tHE

 

UnIt

. d

UctWoRk

 

dIMEnSIonS

 

aRE

 

SHoWn

 

In

 R

oof

 c

URb

 I

nStallatIon

 I

nStRUctIonS

.

Refer to the Roof Curb Installation Instructions for proper 

curb installation. Curbing must be installed in compliance 

with the National Roofing Contractors Association Manual.

To assist in determining rigging requirements, unit weights 

and center of gravity  are shown as follows:

WEIGHTS AND CENTER OF GRAVITY

Y

X

CG

COMPRESSOR

CONDENSER COIL

RETURN

EVAPORATOR COIL

B

C

D

A

SUPPLY

Corner and center of gravity locations 

Содержание GPG16 M Series

Страница 1: ...ING This forced air central unit design complies with requirements embodied in The American National Standard National Standard of Canada ANSI Z21 47 CSA 2 3 Gas fired central furnaces WARNING PROP 65...

Страница 2: ...any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot...

Страница 3: ...ese installation and operating instructions all local building codes and ordinances or in their absence with the latest edition of the National Fuel Gas Code NFPA54 ANSI Z223 1 and National Standard o...

Страница 4: ...g material according to local codes Pre Installation Checks Carefully read all instructions for the installation prior to installing unit Ensure each step or procedure is understood and any special co...

Страница 5: ...ngs building openings or openable windows must be maintained in accordance with the latest edition of the National Fuel Gas Code ANSI Z223 1 NFPA 54 Minimum horizontal clearance of 48 from the furnace...

Страница 6: ...ir into the unit fresh air intake NOTE If the 36 minimum clearance is used on the control panel side of unit a flue extension kit needs be to installed to prevent flue gas recirculation See table belo...

Страница 7: ...the unit must not be less than 60 Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables Spreader bars must be of sufficient length so that cables do not come in...

Страница 8: ...ng from sharp edges follow national electrical code and all local codes and ordinances Do not route wires through removable access panels CAUTION Conduit and fittings must be weather tight to prevent...

Страница 9: ...k connections control box note depending on the options installed the location of the components may vary in some models WARNING Failure of unit due to operation on improper line voltage or with exces...

Страница 10: ...efer to unit wiring diagrams for thermostat or remote sensor connections GAS SUPPLY PIPING WARNING To prevent personal injury or death due to improper installation adjustment alteration service or mai...

Страница 11: ...threads only Pipe joint compound must be resistant to the action of the fuel used 3 Use ground joint unions 4 Install a drip leg to trap dirt and moisture before it can enter the gas valve The drip le...

Страница 12: ...to convert units to propane gas NOx screens must be removed before converting to LP Remove burner assembly and pull NOx screens from each burner tube When all the screens are out reassemble the burner...

Страница 13: ...supply gas pressure is less than 11 0 w c or greater than 13 0 w c 6 All pipe connections should be sealed with a pipe thread compound which is resistant to the fuel used with the furnace A soapy wat...

Страница 14: ...Checks procedure provides a step by step sequence which if followed will assure the proper startup of the equipment in the minimum amount of time Air balancing of duct system is not considered part o...

Страница 15: ...Motor Adjust the CFM for the unit by changing the position of the low voltage leads on the terminal block TB1 Refer to Appendix A for blower performance at each speed tap Refer to Appendix D for maxi...

Страница 16: ...16 Wiring Example...

Страница 17: ...rmal manifold pressure for High fire is 3 5 w c on natural gas and 10 0 w c for propane gas Low fire natural gas 2 0 w c 6 0 w c low fire propane gas Minimum gas supply pressure is 5 0 w c for natural...

Страница 18: ...Gas Only Check It is the responsibility of the contractor to adjust the gas input to the unit To measure the gas input use a gas meter and proceed as follows 1 Turn off gas supply to all other applian...

Страница 19: ...speed will lower the temperature rise A slower blower speed will increase the temperature rise NOTE Blower speed MUST be set to give the correct air temperature rise through the unit as marked on the...

Страница 20: ...prior to resetting this manual reset control WARNING To avoid property damage personal injury or death due to fire or explosion a qualified servicer must investigate the reason for the rollout protec...

Страница 21: ...the compressor control circuits will be ready to respond to a subsequent call for cooling Refrigeration Performance Check Check that compressor RLA corresponds to values shown in Appendix B RLA draw c...

Страница 22: ...remove the filter access panel on return side of the unit Cabinet Finish Maintenance Use a fine grade automotive wax on the cabinet finish to maintain the finish s original high luster This is especi...

Страница 23: ...dicates an internal fault check power supply to unit for proper voltage check all fuses circuit breakers and wiring Disconnect electric power for five seconds If LED remains off after restoring power...

Страница 24: ...ce 4 FLASH CODE If the primary limit switch opens the gas valve is immediately deenergized the induced draft and air circulating blowers are energized The induced draft and air circulator blowers rema...

Страница 25: ...62 859 0 62 0 2 1901 912 0 66 0 4 1787 909 0 66 0 4 1824 966 0 70 0 6 1702 955 0 69 0 6 1737 1014 0 73 0 8 1625 1005 0 73 0 8 1658 1067 0 77 0 2 2132 954 0 91 0 2 2175 1014 0 97 0 4 2056 993 0 95 0 4...

Страница 26: ...4 70 0 70 0 7 2 6 5 50 6 49 9 70 0 70 0 Power Supply Model Number Electrical Rating Compressor Outdoor Fan Motor Indoor Fan Motor Optional Electric Heat Optional Powered Convienience Outlet FLA Optio...

Страница 27: ...CURB LOCATION EMBOSS FOR THRU THE BASE UTILITIES RETURN 11 X 25 SUPPLY 12 X 17 Horizontal Discharge Vertical Discharge NOTE Refer to IOD 7082 included in the literature pack for installing horizontal...

Страница 28: ...28 APPENDIX D MIN MAX AIRFLOW UNIT HEAT RANGE HIGH FIRE RATE BTU HR HEATING MINIMUM SCFM COOLING MINIMUM SCFM MAXIMUM SCFM GPG1660140M41 HIGH 140 000 1615 1500 2500 AIR FLOW RANGE FOR HIGH STAGE...

Страница 29: ...RD YL YL BL VMC A1 A2 LS RD RD BK BK YL YL BK BK PU PU BK BK RS BK BK BK BK LPS ALS GAS PLM GAS PLF GR GY PU PU BL BR TN PU PU PU BL BR TN VM L1 L2 T1 T2 VMC F3 F3 FB3 4 BK RD PK BL BR GR YL WH PU GR...

Страница 30: ...30...

Страница 31: ...31...

Страница 32: ...o the feedback page GOODMAN BRAND AMANA BRAND GOODMAN BRAND AMANA BRAND PRODUCT REGISTRATION Thank you for your recent purchase Though not required to get the protection of the standard warranty regis...

Отзывы: