BLOWER PERFORMANCE DATA

X = Outside of Temperature Rise Range - Not Recommended.

NOTE: 

The shaded area indicates ranges in excess of maximum external static pressure allowable when heating. For satisfactory operation,

external static pressure should not exceed 0.5" w.c.

CFM

WATTS

RISE

CFM

WATTS

RISE

CFM

WATTS

CFM

WATTS

CFM

WATTS

0.1

729

55

52

913

103

57

897

99

897

99

1047

139

0.2

680

63

57

864

111

61

848

107

848

107

998

146

0.3

631

71

62

815

119

64

799

115

799

115

948

154

0.4

582

79

X

766

127

X

750

123

750

123

899

162

0.5

532

87

X

717

135

X

701

131

701

131

850

170

0.6

---

---

---

667

143

X

652

139

652

139

801

178

0.7

---

---

---

---

---

---

---

---

---

---

---

---

0.8

---

---

---

---

---

---

---

---

---

---

---

---

CFM

WATTS

RISE

CFM

WATTS

RISE

CFM

WATTS

CFM

WATTS

CFM

WATTS

0.1

1050

139

49

1256

220

55

1123

168

1123

168

1326

248

0.2

1006

147

52

1211

228

57

1079

176

1079

176

1282

256

0.3

961

154

54

1167

236

59

1034

183

1034

183

1237

263

0.4

916

162

57

1122

243

62

989

191

989

191

1192

271

0.5

872

170

60

1077

251

64

945

199

945

199

1148

279

0.6

827

178

63

1033

259

68

900

206

900

206

1103

287

0.7

782

185

69

988

267

70

855

214

855

214

---

---

0.8

738

193

72

---

---

---

811

222

811

222

---

---

CFM

WATTS

RISE

CFM

WATTS

RISE

CFM

WATTS

CFM

WATTS

CFM

WATTS

0.1

1053

143

49

1257

236

55

1184

203

1184

203

1408

304

0.2

1007

151

52

1211

243

57

1138

210

1138

210

1362

311

0.3

961

158

54

1165

250

59

1092

217

1092

217

1315

319

0.4

915

165

57

1119

258

62

1046

225

1046

225

1269

326

0.5

869

173

60

1073

265

64

1000

232

1000

232

1223

334

0.6

823

180

63

1027

273

68

954

240

954

240

1177

341

0.7

777

188

69

980

280

70

908

247

908

247

---

---

0.8

731

195

72

---

---

---

862

255

862

255

---

---

CFM

WATTS

RISE

CFM

WATTS

RISE

CFM

WATTS

CFM

WATTS

CFM

WATTS

0.1

1090

150

52

1286

231

57

1354

260

1354

260

1609

365

0.2

1025

158

57

1225

239

61

1296

267

1296

267

1556

373

0.3

960

166

62

1165

247

64

1237

275

1237

275

1504

381

0.4

895

174

X

1105

255

X

1178

283

1178

283

1451

388

0.5

830

181

X

1045

262

X

1120

291

1120

291

1399

396

0.6

765

189

---

984

270

X

1061

299

1061

299

1347

404

0.7

699

197

---

924

278

---

1002

306

1002

306

1294

412

0.8

634

205

---

---

---

---

944

314

944

314

1242

420

CFM

WATTS

RISE

CFM

WATTS

RISE

CFM

WATTS

CFM

WATTS

CFM

WATTS

0.1

1164

180

56

1435

293

61

1477

310

1477

310

1709

407

0.2

1100

188

59

1378

301

63

1421

318

1421

318

1659

414

0.3

1037

196

62

1322

309

65

1365

326

1365

326

1609

422

0.4

974

204

65

1265

316

68

1310

334

1310

334

1559

430

0.5

910

212

70

1208

324

70

1254

342

1254

342

1509

438

0.6

847

220

75

1152

332

73

1198

349

1198

349

1459

446

0.7

784

227

X

1095

340

X

1143

357

1143

357

1409

453

0.8

720

235

X

1038

348

X

1087

365

1087

365

---

---

CFM

WATTS

RISE

CFM

WATTS

RISE

CFM

WATTS

CFM

WATTS

CFM

WATTS

0.1

1792

514

X

1792

514

58

1366

257

1939

603

2108

704

0.2

1743

522

45

1743

522

61

1317

265

1889

611

2058

713

0.3

1693

530

45

1693

530

61

1267

273

1840

619

2009

721

0.4

1644

538

46

1644

538

63

1218

281

1791

627

1960

729

0.5

1595

546

48

1595

546

65

1169

290

1742

635

1911

737

0.6

1546

554

50

1546

554

68

1120

298

1693

643

---

---

0.7

1496

563

52

1496

563

70

1071

306

1643

651

---

---

0.8

---

---

---

---

---

---

---

---

---

---

   *PG152407041** - Rise Range: 35° - 65° F

E.S.P

T1                  

T2                     

T3              

T4             

T5              

   *PG153009041** - Rise Range: 45° - 75° F

E.S.P

T1                  

1

ST

 Stage Heating 

T2                     

2

nd

 Stage Heating Speed

T3              

Cooling Speed

T4             

Cooling Speed

T5              

Cooling Speed

   *PG153709041** - Rise Range: 45° - 75° F

E.S.P

T1                  

1

ST

 Stage Heating 

Speed

T2                     

2

nd

 Stage Heating Speed

T3              

Cooling Speed

T4             

Cooling Speed

T5              

Cooling Speed

   *PG154211541** - Rise Range: 45° - 75° F

E.S.P

T1                  

1

ST

 Stage Heating 

Speed

T2                     

2

nd

 Stage Heating Speed

T3              

Cooling Speed

T4             

Cooling Speed

T5              

Cooling Speed

   *PG154911541** - Rise Range: 45° - 75° F

E.S.P

T1                  

1

ST

 Stage Heating 

Speed

T2                     

2

nd

 Stage Heating Speed

T3              

Cooling Speed

T4             

Cooling Speed

T5              

Cooling Speed

   *PG156014041** - Rise Range: 45° - 75° F

E.S.P

T1                  

1

ST

 Stage Heating 

Speed

T2                     

2

nd

 Stage Heating Speed

T3              

Cooling Speed

T4             

Cooling Speed

T5              

Cooling Speed

Содержание GPG152407041

Страница 1: ...tion Sheet referred to in this manual RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION ATTENTION INSTALLING PERSONNEL Prior to installation thoroughly familiarize yourself with this Installation Manual Observe all safety warnings During installation or repair caution is to be observed It is your responsibility to install the product safely and to educate the customer on its safe use These installation...

Страница 2: ...ORK 10 FILTERS 11 VENTING 11 INSTALLATION FLUE HOOD EXHAUST 11 INSTALLATION COMBUSTION AIR INTAKE HOOD 11 CONDENSATEDRAIN 11 CONDENSATE DRAIN CONNECTION 11 NORMAL SEQUENCES OF OPERATION 12 HEATING 12 COOLING 12 FAN ONLY 12 STARTUP ADJUSTMENTS AND CHECKS 12 HEATING STARTUP 12 COOLING STARTUP 15 TROUBLESHOOTING 15 IGNITION CONTROL ERROR CODES 15 FAULT RECALL 15 ABNORMAL OPERATION HEATING 16 INTERNAL...

Страница 3: ...E PASSAGES QUALIFIED SERVICER ONLY 17 MAIN BURNER FLAME QUALIFIED SERVICER ONLY 18 CLEANING BURNERS 18 ACCESSORIES AND FUNCTIONAL PARTS 18 SHEET METAL ACCESSORIES 18 FUNCTIONAL PARTS 18 GENERAL INFORMATION 18 APPENDIX 19 IGNITION CONTROL DIAGNOSTIC INDICATOR CHART 21 HEATING TIMING CHART 21 COOLING TIMING CHART 21 UNIT DIMENSIONS 22 PG15 41A WIRING DIAGRAM 23 PG15 41B WIRING DIAGRAM 23 MINIMUM CLE...

Страница 4: ...FFAIRS GOODMAN MANUFACTURING COMPANY L P 7401 SECURITY WAY HOUSTON TEXAS 77040 713 254 4729 SAFETY INSTRUCTIONS TO THE INSTALLER Before installing this unit please read this manual to familiarize yourself on the specific items which must be adhered to including maximum external static pressure to unit air temperature rise minimum or maximum CFM and motor speed connections TO THE OWNER A warranty c...

Страница 5: ...ed by compounds containing chlorine or fluorine Common sources of such compounds include swimming pool chemicals and chlorine bleaches paint stripper adhesives paints varnishes sealers waxes which are not yet dried and solvents used during construction and remodeling Various commercial and industrial processes may also be sources of chlorine fluorine compounds To avoid possible illness or death of...

Страница 6: ...54 ANSI Z223 1 and National Standard of Canada CAN CSA B149 Installation Codes The heating and cooling capacities of the unit should be greater than or equal to the design heating and cooling loads of the area to be conditioned The loads should be calculated by an approved method or in accordance with A S H R A E Guide or Manual J Load Calculations published by the Air Conditioning Contractors of ...

Страница 7: ...to the Installation Manual provided with the LP kit for conversion from natural gas to propane gas and for altitude adjustments Use HA02 for installations above 2000 PIPING IMPORTANTNOTE To avoid possible unsatisfactory operation or equipment damage due to under firing of equipment do not undersize the natural propane gas piping from the meter tank to the unit When sizing a trunk line include all ...

Страница 8: ... procedure The unit is placed in operation by closing the main electrical disconnect switch for the unit PROPANE GAS INSTALLATIONS IMPORTANTNOTE Propane gas conversion kits must be installed to convert units to propane gas Refer to the gas piping section for the correct LP kit for conversion All propane gas equipment must conform to the safety standards of the National Board of Fire Underwriters S...

Страница 9: ...649 70 196 446 824 1 394 2 146 1 165 2 437 80 182 412 767 1 297 1 996 1 084 2 267 90 171 386 719 1 217 1 873 1 017 2 127 100 161 365 679 1 149 1 769 961 2 009 150 130 293 546 923 1 421 772 1 613 200 111 251 467 790 1 216 660 1 381 250 90 222 414 700 1 078 585 1 224 300 89 201 378 634 976 530 1 109 350 82 185 345 584 898 488 1 020 400 76 172 321 543 836 454 949 To convert to Capacities at 15 PSIG S...

Страница 10: ... through Goodman s Service Parts department DuctCoverInstallation DownDischargeApplications Cut insulation around bottom openings and remove panels from the bottom of the unit saving the screws holding the panels in place NOTE Single phase models require installation of horizontal duct kit 20464501PDGK medium chassis and 20464502PDGK large chassis DUCTWORK Duct systems and register sizes must be p...

Страница 11: ... must be a means of filtering all return air All units may be externally filtered Refer to the unit filter size chart in the appendix for filter size information Filters installed external to the unit should be sized in accordance with their manufacturer recommendations A throwaway filter must be sized for a maximum face velocity of 300 feet per minute FilterInstallation IMPORTANTNOTE When install...

Страница 12: ...l is for high stage cooling the compressor and outdoor fan are energized at high stage 3 The indoor blower will energize approximately 6 seconds later 4 The unit delivers cooling to the conditioned space until the thermostat is satisfied 5 The compressor and outdoor fan will be de energized when the thermostat opens 6 The indoor blower continues to run at low cool speed for approximately 60 second...

Страница 13: ...M Outlet Pressure Boss Open to Atmosphere White Rodgers Model 36G54 connected to Manometer Gas Supply And Manifold Check Gas supply pressure and manifold pressure with the burners operating must be as specified on the rating plate Gas Inlet Pressure Check Gas inlet pressure must be checked and adjusted in accordance to the type of fuel being consumed With Power And Gas Off 1 Connect a water manome...

Страница 14: ...w c Gas Manifold Gas Pressure 8 Remove regulator cover screw from the low LO outlet pressure regulator adjust tower and turn screw clockwise to increase pressure or counterclockwise to decrease pressure 9 Energize main M solenoid as well as the HI terminal 10 Remove regulator cover screw from the HI outlet pressure regulator adjust tower and turn screw clockwise to increase pressure or countercloc...

Страница 15: ...rol is equipped with a momentary push button switch that can be used to display on the diagnostic LED the last five faults detected by the control The control must be in Standby Mode no thermostat inputs to use the feature Depress the push button switch for approximately 2 seconds NOTE Do not hold for longer than 4 seconds Holding the button for 4 seconds or higher will erase the memory Release th...

Страница 16: ... fault is three 3 flashes OPEN THERMAL PROTECTION DEVICE If a limit switch opens the gas valve is immediately de energized the induced draft and air circulating blowers are energized The induced draft and air circulator blowers remain energized until the limit switch re closes The diagnostic LED red code for an open limit is four 4 flashes PRIMARY LIMIT A primary limit will open due to excessive s...

Страница 17: ...anable it should be replaced CABINET FINISH MAINTENANCE Use a fine grade automotive wax on the cabinet finish to maintain the finish s original high luster This is especially important in installations with extended periods of direct sunlight CLEAN OUTSIDE COIL QUALIFIED SERVICER ONLY The coil with the outside air flowing over it should be inspected annually and cleaned as frequently as necessary ...

Страница 18: ... For further information on the yearly inspection consult the User Manual It is recommended that a qualified servicer inspect and service the unit at least once each year Turn the unit on at the thermostat Wait a few minutes since any dislodged dust will alter the normal flame appearance Flames should be predominantly blue and directed into the tubes They should not be yellow They should extend di...

Страница 19: ...19 APPENDIX ...

Страница 20: ...es Indoor Outdoor Thermostat Open Cooling Only Devices Not present On All Models 9 Flashes High Pressure Loss of Charge Switch Open Cooling Only Devices Not Present On All Models Amber Light Signal Refer to Abnormal Heating or Cooling Operation Sections of this Manual Off No Flame Present On Normal Flame 1 Flash Low Flame Current 2 Flashes Flame Detected with Gas Valve De energized 90 120 150 180 ...

Страница 21: ...UPPLY ENTRANCE CONDENSATE DRAIN CONNECTION 3 4 NPT FEMALE 16 1 8 19 1 8 EVAPORATOR CONTROL PANEL ACCESS PANEL 4 3 4 B 7 15 16 16 B 5 1 2 1 3 8 16 2 3 4 A 18 7 16 FLUE EXHAUST 51 47 BLOWER ACCESS PANEL 22 22 11 11 3 SUPPLY RETURN SUPPLY RETURN 5 3 4 5 1 4 C 20 24 DIMENSION INCHES MEDIUM LARGE A 32 40 B 16 18 C 9 1 2 14 CENTER OF GRAVITY COMBUSTION AIR INTAKE FLUE EXHAUST HOOD UNIT DIMENSIONS ...

Страница 22: ...BR PU OR OR OR RD BK BK RD BL PU PU PU PU OR BR WH BL BK PU BL PU YL IGN FS OR LS SOL HI LOW ODF L1 HIGH 6 3 1 2 4 5 1 2 3 4 5 6 7 8 9 NONE 5 MIN 10 MIN 180 150 120 90 Y2 Y1 G W2 W1 C R BLOWER OFF DELAY STAGE DELA Y ECON LO HEAT HI HEAT HI COOL LO COOL FS T1 LOW INDUCER L2 C H M PU BK YL YL H C F RD PU YL RD GR SEE NOTE 3 EM 208 PU YL PU BK N G L BR BR 240 3 TR 2 RD 24V C 1 YL BL 208 230 1 60 POWE...

Страница 23: ...LO COOL HI HEAT LO HEAT P2 MVC MVH MVL PSW PSW HLO TH 2 3 5 6 4 1 5 7 9 8 6 3 1 2 L1 L1 HI LO HI SOL GV EM C CC C HI M RS PS LS ALS TR EM VM H F C L2 T2 208 230 1 60 CM L1 R T1 S C SUPPLY VOLTAGE P1 INTEGRATED IGNITION CONTROL CHECK CHECK FOR SHORTS IN FLAME SENSOR WIRING NORMAL FLAME PRESENT DIAGNOSTIC LED AMBER GAS PRESSURE FLAME SENSOR GAS VALVE GAS FLOW CHECK GAS VALVE ON OFF 1 FLASH 2 FLASHES...

Страница 24: ...ORE SERVICING ULTIPLE POWER SOURCES MAY BE PRESENT AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH Wiring is subject to change Always refer to the wiring diagram on the unit for the most up to date wiring PG15 41B WIRING DIAGRAM ...

Страница 25: ...ORE SERVICING ULTIPLE POWER SOURCES MAY BE PRESENT AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH Wiring is subject to change Always refer to the wiring diagram on the unit for the most up to date wiring PG15 41B WIRING DIAGRAM ...

Страница 26: ...o more than 36 3 MIN 12 MIN 12 MIN 36 MIN FOR SERVICE 48 MIN MINIMUM CLEARANCES RECOMMENDED FILTER SIZES UNIT 2 Ton 2 1 2 Ton 3 Ton 3 1 2 4 Ton 5 Ton Min Filter Size 1 20 x 20 x 1 1 20 x 25 x 1 1 25 x 25 x1 2 20 x 20 x 1 2 20 x 25 x 1 ...

Страница 27: ... 1237 275 1504 381 0 4 895 174 X 1105 255 X 1178 283 1178 283 1451 388 0 5 830 181 X 1045 262 X 1120 291 1120 291 1399 396 0 6 765 189 984 270 X 1061 299 1061 299 1347 404 0 7 699 197 924 278 1002 306 1002 306 1294 412 0 8 634 205 944 314 944 314 1242 420 CFM WATTS RISE CFM WATTS RISE CFM WATTS CFM WATTS CFM WATTS 0 1 1164 180 56 1435 293 61 1477 310 1477 310 1709 407 0 2 1100 188 59 1378 301 63 1...

Страница 28: ...IED SERVICER ONLY Your package unit should be inspected by a qualified installer or service agency at least twice every year This check should be performed before the heating and cooling seasons begin This will ensure that adequate combustion air is being drawn and the vent system is working properly Particular attention should be paid to the following items Repair as necessary Check physical supp...

Отзывы: