8
PRODUCT DESIGN
ELECTRICAL DATA (*Blower Only, Heat Mode)
All wires and overcurrent protection devices are sized for use with electric heaters only and without
refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See
PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent
protection during refrigeration cycle.
IMPORTANT NOTE:
A separate power supply is required for the HKR heater kit.
WARNING
WARNING
*PC13[24-60]H41**
Maximum
Maximum
Overcurrent
Overcurrent
Protection (a mps)
Protection (am ps)
at 208 / 240V
at 208 / 240V
*PC1324H41**
--
--
--
--
HKR05*,C*
24 / 27
30 / 30
--
--
4.75 / 16,200
HKR08*,C*
33 / 38
40 / 40
--
--
7 .0 / 23,800
HKR10*,C*
45 / 51
60 / 60
--
--
9 .5 / 32,400
*PC1330H41**
2.4 / 2.4
--
--
--
--
HKR05*,C*
24 / 27
30 / 30
--
--
4.75 / 16,200
HKR08*,C*
34 / 39
40 / 40
--
--
7 .0 / 23,800
HKR10*,C*
45 / 52
60 / 60
--
--
9 .5 / 32,400
HKR15*,C*
45 / 52
60 / 60
22 / 25
30 / 30
14 .25 / 48,600
*PC1336H41**
--
--
--
--
HKR05*,C*
24 / 27
30 / 30
--
--
4.75 / 16,200
HKR08*,C*
34 / 39
40 / 40
--
--
7 .0 / 23,800
HKR10*,C*
45 / 52
60 / 60
--
--
9 .5 / 32,400
HKR15*,C*
45 / 52
60 / 60
22 / 25
30 / 30
14 .25 / 48,600
*PC1342H41**
--
--
--
--
HKR05*,C*
25 / 27
30 / 30
--
--
4.75 / 16,200
HKR08*,C*
34 / 39
40 / 40
--
--
7 .0 / 23,800
HKR10*,C*
46 / 52
60 / 60
--
--
9 .5 / 32,400
HKR15*,C*
46 / 52
60 / 60
22 / 25
30 / 30
14 .25 / 48,600
HKR20*,C*
46 / 52
60 / 60
43 / 49
60 / 60
19.5 / 66,500
*PC1348H41**
--
--
--
--
HKR05*,C*
25 / 28
30 / 30
--
--
4.75 / 16,200
HKR08*,C*
34 / 40
40 / 40
--
--
7 .0 / 23,800
HKR10*,C*
46 / 53
60 / 60
--
--
9 .5 / 32,400
HKR15*,C*
46 / 52
60 / 60
22 / 25
30 / 30
14 .25 / 48,600
HKR20*,C*
46 / 52
60 / 60
43 / 49
60 / 60
19.5 / 66,500
*PC1349H41**
--
--
--
--
HKR05*,C*
25 / 28
30 / 30
--
--
4.75 / 16,200
HKR08*,C*
34 / 40
40 / 40
--
--
7 .0 / 23,800
HKR10*,C*
46 / 53
60 / 60
--
--
9 .5 / 32,400
HKR15*,C*
46 / 52
60 / 60
22 / 25
30 / 30
14 .25 / 48,600
HKR20*,C*
46 / 52
60 / 60
43 / 49
60 / 60
19.5 / 66,500
*PC1360H41**
--
--
--
--
HKR05*,C*
26 / 30
30 / 30
--
--
4.75 / 16,200
HKR08*,C*
36 / 40
40 / 40
--
--
7 .0 / 23,800
HKR10*,C*
48 / 54
60 / 60
--
--
9 .5 / 32,400
HKR15*,C*
48 / 54
60 / 60
22 / 25
30 / 30
14 .25 / 48,600
HKR20*,C*
48 / 54
60 / 60
43 / 49
60 / 60
19.5 / 66,500
Actual
kW & BTU
at 240 V
Minimum Circ uit
Ampacity
at 208 / 240V
Minimum Circ uit
Ampacity
at 2 08 / 240V
Model and
Heat Kit Usage
Circuit #1
Circuit #2