WIRING DIAGRAMS

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

GMH950905CXAA

HIGH VOL

T

A

G

E

!

DIS

C

ONNECT

 AL

L

 POW

E

R BEF

O

RE

 SERVICI

NG OR IN

S

T

A

L

L

IN

G

 T

H

IS

UNIT

 M

U

L

T

IPL

E

 PO

W

E

R SO

UR

CES M

A

Y BE P

R

ESEN

T

 F

A

IL

URE 

T

O

DO SO 

M

A

Y CAUS

E PROP

ERT

Y

 DAM

AG

E, 

PERSONAL

 I

N

J

U

R

Y

 OR DE

A

T

H

.

R

YL YELLOW
OR ORANGE

PU PURPLE
GN GREEN
BK BLACK

BR BROWN
WH WHITE

BL BLUE

GY GRAY
RD RED

COLOR CODES:

LOW VOLTAGE (24V)

LOW VOLTAGE FIELD

HI VOLTAGE (115V)

HI VOLTAGE FIELD

NOTES:

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.

0140F00647 REV. B

 OR (MED LOW)

 BL (MED)

 RD (LOW)

GAS VALVE

C

PM

C

G

W

       INTERNAL TO

INTEGRATED CONTROL

JUNCTION

EQUIPMENT GND

FIELD GND

DIAGNOSTIC
LED

2 CIRCUIT 
CONNECTOR

HOT
SURFACE
IGNITER

 OVERCURRENT

PROT. DEVICE

IGNITER

TH (3)

INTEGRATED 
CONTROL MODULE

JUNCTION BOX

LINE-H

XFMR-H

IN
TEG

R

A

T

ED 
C

O

NT
ROL 

MOD

U

LE

IN
TE
GR

A

T

ED

 CO

NTR

O

MODU

LE

GND

DISCONNECT

L

N

DISCONNECT POWER
BEFORE SERVICING.
WIRING TO UNIT
MUST BE
PROPERLY
POLARIZED
AND GROUNDED.

OVERCURRENT PROTECTION DEVICE

OR

GY

RD

BL

BK

4. IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME, DISCARD JUMPER BEFORE CONNECTING BLOWER LEADS. UNUSED

   BLOWER LEADS MUST BE PLACED ON "PARK" TERMINALS OF INTEGRATED CONTROL OR TAPED.

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL

HAVING A TEMPERATURE RATING OF AT LEAST 105

TERMINAL

SWITCH (PRESS.)

5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.

PK PINK

115 VAC HOT AND PARK TERMINALS

LINE-H

FLAME 
SENSOR

FRONT COVER
PRESSURE SWITCH

( SINGLE CONTROL ON 45K BTU )

N
O

C

GY

BK

PLUG CONNECTION

FIELD SPLICE

SWITCH (TEMP.)

OR

24V THERMOSTAT

CONNECTIONS

GR

GND

115 VAC

24 VAC

BLOWER 
COMPARTMENT 
DOOR SWITCH
(OPEN WHEN 
 DOOR OPEN) 

DOOR
SWITCH

WARNING:DISCONNECT POWER BEFORE 
SERVICING.WIRING TO UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.

BK

GND

DISCONNECT

L

N

WH

JUNCTION
 BOX

1

 OR

ID BLOWER 
PRESSURE 
SWITCH

HEAT-H

GND

WH

RD

WH

GND

BURNER COMPARTMENT

BLOWER COMPARTMENT

NOTE 4

SEE

N
O

COOL-H

 BK (HI)

BR

BR

CAPACITOR

YL

WH

YL

CONTROL

PRIMARY LIMIT

AUTO RESET

BL

PU

MANUAL RESET ROLLOUT LIMIT CONTROL(S)

 RD

OR

PK

BK

WH

WH

BLOWER

INDUCED DRAFT

C

CIRCULATOR 

BLOWER

FS

HI

 

HE

AT

-H

LO

 

HE

AT-

H

IGNITER

HOT SURFACE

IND

IGN

EAC-H

AIR CLEANER

ELECTRONIC

BLWR

CIRCULATOR

BLWR

ID

FLAME SENSOR

115 VAC

TRANSFORMER

40 VA

24 VAC

GND

LIMIT CONTROL

AUTO RESET PRIMARY

(SINGLE CONTROL ON 45K BTU)

LIMIT CONTROL(S)

MANUAL RESET ROLLOUT

RO1 (5)

RO2 (11)

HLO (1)

HLI (7)

MVC (9)

GND (8)

TR (6)

OR

WH

WH

BL

YL

OR

RD

GR

BR

 PK

PU

GY

WH

115

 VA
C

 NE
UT
RA
L

BK

BK

GY

24
V

 T

HER

MOST

AT 
CON

NEC

TI

ONS

MICRO

TO

C

G

Y

W

R

TRANSFORMER

40 VA

2

WH

OR

BL

YL

OR

OR

GY

PU

RD

OR

GY

WH

XF
M

R

-H

TE
R

M

IN

A

L

S

GY

OR

GR

BR

1

2

3

12

11

10

9

8

7

6

5

4

WARNING: 

°C. USE COPPER CONDUCTORS ONLY.

24 VAC

HUMIDIFIER

24 VAC

HUMIDIFIER

HUMIDIFIER

PSO (4)

PS (10)

0

C

7

6

5

4

3

2

1

OFF               = CONTROL FAILURE

   STEADY ON = NORMAL OPERATION

   1 FLASH       =

   2 FLASHES  = PRESSURE SWITCH STUCK CLOSED

   3 FLASHES  = PRESSURE SWITCH STUCK OPEN

   4 FLASHES  = OPEN HIGH LIMIT

   5 FLASHES  = FLAME SENSE WITHOUT GAS VALVE

 OPEN ROLLOUT OR OPEN FUSE

   7 FLASHES  = LOW FLAME SIGNAL

   6 FLASHES  =

SYSTEM LOCKOUT (RETRIES EXCEEDED)

   CONTINUOUS/RAPID FLASHES = REVERSED 115 VAC POLARITY

CONTROL

MODULE

INTEGRATED

FUSE

HI

BR

OR

MVH (12)

FACTORY SETTINGS 
SHOWN

TO 115VAC/ 1

Ø /60 HZ POWER SUPPLY WITH

GY

Y

6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN
    STANDBY (NO THERMOSTAT INPUTS)

BK

LI

NE

 NE

UTR

A

L

S

8

   8 FLASHES  = CHECK IGNITER OR IMPROPER GROUNDING

PU

GY

(HONEYWELL)

NO

C

C

PRESSURE SWITCH

FRONT COVER

NO

AUXILIARY LIMIT CONTROLS

HI

C

VALVE

GAS

PM

MVL(2)

ID BLOWER
PRESSURE

SWITCH

ON

OFF

2ND 
STAGE 
DELAY

MODE

HEAT 
OFF 
DELAY

FS

1

2

3

*

*

*

*

SEE 
NOTE 6

COOL-H

Содержание GMH95

Страница 1: ...og for part number information Model numbers listed on page 3 Copyright 2007 2009 2010 Goodman Manufacturing Company L P TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL...

Страница 2: ...onnect ALL power before servicing or installing this unit Multiple power sources may be present Failure to do so may cause property damage personal injury or death Installation and repair of this unit...

Страница 3: ...o follow these regulations may harm the environment and can lead to the imposition of substantial fines These regulations may vary by jurisdiction Should questions arise contact your local EPA office...

Страница 4: ...rts in Service Instructions General Operation The GMH95 furnaces are equipped with an electronic igni tion device used to light the burners and an induced draft blower to exhaust combustion products A...

Страница 5: ...as Line Entrance 14 Flue Pipe Connection Alternate 15 Rubber Elbow 16 Induced Draft Blower 17 Electrical Connection Inlets Alternate 18 Coil Front Cover Pressure Tap 19 Coil Front Cover Drain Port 20...

Страница 6: ...SIDE CUT OUT LOW VOLTAGE ELECTRICAL HOLE RIGHT SIDE DRAIN LINE HOLES STANDARD GAS SUPPLY HOLE DRAIN TRAP 19 3 4 AIR INTAKE PIPE 2 PVC LEFT SIDE DRAIN LINE HOLES 1 5 8 RIGHT SIDE VIEW CONDENSATE DRAIN...

Страница 7: ...5 0 10 0 10 20197308 1 35 0130F00110 TBD TBD TBD GMH950905DXA 1 30 1 10 0 52 0 37 0 37 20197312 1 10 0130F00000P TBD TBD TBD GMH951155DXA 1 30 1 10 0 75 0 60 0 60 20197310 1 10 0130F00000P TBD TBD TBD...

Страница 8: ...LIMIT Part Number 10123514 or 10123533 10123517 Open Setting F 200 210 GMH950453BXA 1 GMH950703BXA 2 GMH950704CXA 2 GMH950904CXA 2 GMH950905CXA 2 GMH950905DXA 2 GMH951155DXA 2 ROLLOUT LIMIT SWITCHES...

Страница 9: ...C D heights have an insulated Z bracket for use with one size smaller furnace All proper coil combinations are subject to being ARI rated with a matched outdoor unit C A P F 1824 A 6 A PRODUCT TYPE C...

Страница 10: ...filter face velocity Minimum filter area dictated by heating airflow requirement Cabinet Width in Nominal Filter Size in Approx Flow Area in 2 Cabinet Width in Nominal Filter Size in Approx Flow Area...

Страница 11: ...MH95 0703BXA GMH95 0704CXA GMH95 0904CXA GMH95 0905CXA GMH95 0905DXA GMH95 1155DXA Btuh Input US 46 000 69 000 69 000 92 000 92 000 92 000 115 000 Output US 44 400 66 400 66 900 89 000 88 400 88 400 1...

Страница 12: ...57 973 904 793 MED H I MED LO 2 0 981 61 962 62 943 63 917 65 888 67 830 764 665 LOW 1 5 750 79 730 81 714 83 692 86 657 90 620 570 502 H IGH 4 0 2069 29 1965 30 1871 32 1756 34 1661 36 1549 1415 127...

Страница 13: ...0 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULA...

Страница 14: ...FIELD SPLICE SWITCH TEMP OR 24V THERMOSTAT CONNECTIONS GR GND 115 VAC 24 VAC BLOWER COMPARTMENT DOOR SWITCH OPEN WHEN DOOR OPEN DOOR SWITCH BK GND L N WH JUNCTION BOX 1 OR ID BLOWER PRESSURE SWITCH H...

Страница 15: ...ITCH HEAT H GND WH RD WH GND BURNER COMPARTMENT BLOWER COMPARTMENT NOTE 4 SEE N O COOL H BK HI BR BR CAPACITOR YL WH YL CONTROL PRIMARY LIMIT AUTO RESET BL PU MANUAL RESET ROLLOUT LIMIT CONTROL S RD O...

Страница 16: ...COMPARTMENT DOORSWITCH OPENWHEN DOOROPEN DOOR SWITCH WARNING DISCONNECTPOWERBEFORE SERVICING WIRINGTOUNITMUSTBE PROPERLYPOLARIZEDANDGROUNDED BK GND DISCONNECT L N WH JUNCTION BOX 1 OR IDBLOWER PRESSU...

Отзывы: